Section 1:
ADT-LCD40 Series Annunciators
Note: Only Model ADT-LCD40L is listed for use in Canada.
The ADT-LCD40 Series Annunciators are compact, attractive,
40-character, backlit LCD fire annunciators designed for use with the
Unimode 200 Addressable Fire Alarm Control Panel. The
ADT-LCD40L operates the same as the ADT-LCD40, except it does not
have function switches or a key-switch. It should be noted that the
ADT-LCD40 Series Annunciator displays will mimic the LCD display
located on the Unimode 200 main circuit board.
40-character, backlit LCD fire annunciators designed for use with the
Unimode 200 Addressable Fire Alarm Control Panel. The
ADT-LCD40L operates the same as the ADT-LCD40, except it does not
have function switches or a key-switch. It should be noted that the
ADT-LCD40 Series Annunciator displays will mimic the LCD display
located on the Unimode 200 main circuit board.
If software with Part Number #UNIMODE200V3.0 is installed in the
ADT Unimode 200, the ADT-LCD40 Series Annunciator must have soft-
ware with a Part Number of 73879 to operate with the control panel. If
software with a Part Number of #UNIMODE200V4.0 or higher is
installed in the Unimode 200, the ADT-LCD40 Series Annunciator must
have software with a Part Number of #LCD40V2.0 or higher to operate
with the control panel.
ADT Unimode 200, the ADT-LCD40 Series Annunciator must have soft-
ware with a Part Number of 73879 to operate with the control panel. If
software with a Part Number of #UNIMODE200V4.0 or higher is
installed in the Unimode 200, the ADT-LCD40 Series Annunciator must
have software with a Part Number of #LCD40V2.0 or higher to operate
with the control panel.
The ADT-LCD40 Series is capable of displaying English-language text
of system point status including device type, independent point alarm,
trouble or supervisory, zone and custom alpha labels programmed into
the control panel. The ADT-LCD40 Series also provide system status
LEDs to display Power, Alarm, Trouble and Supervisory conditions.
The ADT-LCD40 is capable of performing system acknowledge,
silence, drill and reset remotely while the ADT-LCD40L does not have
these features.
of system point status including device type, independent point alarm,
trouble or supervisory, zone and custom alpha labels programmed into
the control panel. The ADT-LCD40 Series also provide system status
LEDs to display Power, Alarm, Trouble and Supervisory conditions.
The ADT-LCD40 is capable of performing system acknowledge,
silence, drill and reset remotely while the ADT-LCD40L does not have
these features.
Communication between the control panel and the ADT-LCD40 Series
is accomplished over a two-wire serial interface employing the EIA-485
communication standard. Up to 32 annunciators may be connected to
the two-wire EIA-485 circuit. The annunciators may be powered from
the host FACP or remote UL listed, filtered, power supplies.
is accomplished over a two-wire serial interface employing the EIA-485
communication standard. Up to 32 annunciators may be connected to
the two-wire EIA-485 circuit. The annunciators may be powered from
the host FACP or remote UL listed, filtered, power supplies.