ADIC Time Clock 6-00028-01 Rev A Manuel D’Utilisation

Page de 446
Managing the AMASS File System
6-00028-01 Rev A
Operational Tasks
2-37
MAXIOSZ Changes
If you want to change the 
MAXIOSZ
, perform the following 
steps: 
Step
Command
1
Log in as 
amass
 or 
root
.
2
Remove your current Backup Volume (containing a backup 
of the AMASS File System Database and transaction file) 
from the library, label it with the “old” 
MAXIOSZ
 value, and 
store the volume in a safe place. 
3
Upgrade to the current version of AMASS. 
4
Immediately create a new Backup Volume with the 
amassbackup
 command. 
5
Label the new Backup Volume with the “new” 
MAXIOSZ
 
value. 
6
To recover data on the old Backup Volume, return the 
MAXIOSZ
 parameter on AMASS to the old setting before 
attempting to read the old Backup Volume