Managing the AMASS File System
6-00028-01 Rev A
Operational Tasks
2-37
MAXIOSZ Changes
If you want to change the
MAXIOSZ
, perform the following
steps:
Step
Command
1
Log in as
amass
or
root
.
2
Remove your current Backup Volume (containing a backup
of the AMASS File System Database and transaction file)
from the library, label it with the “old”
of the AMASS File System Database and transaction file)
from the library, label it with the “old”
MAXIOSZ
value, and
store the volume in a safe place.
3
Upgrade to the current version of AMASS.
4
Immediately create a new Backup Volume with the
amassbackup
amassbackup
command.
5
Label the new Backup Volume with the “new”
MAXIOSZ
value.
6
To recover data on the old Backup Volume, return the
MAXIOSZ
parameter on AMASS to the old setting before
attempting to read the old Backup Volume