Delta Tau GEO BRICK DRIVE Manuel D’Utilisation

Page de 294
 Geo Brick Drive User Manual 
Pinouts and Software Setup 
 147 
With Servo IC 0 sourcing the clock at its enhanced settings (9.0 KHz PWM), the following are suggested 
Servo IC 1 clock settings which would provide a good analog output signal: 
 
Servo IC 0 
Clock Settings 
Resulting 
Frequencies KHz 
 
 
 
 
Servo IC 1 
Clock Settings 
Resulting  
Frequencies KHz 
I7000=3275 
I7001=0 
I7002=3 
I10=1863964 
PWM 
PHASE 
SERVO 
9.0 
18 
4.5 
 
 
 
 
I7100=816 
I7101=3 
I7102=3 
I7104=0
 
PWM 
PHASE 
SERVO 
PWM
Deadtime
 
36 
18 
4.5 
0 
 
 
 
 
 
 
 
 
 
 
 
 
Note that n=4 in this case 
 
 
Note 
These  Servo  IC  1  clock  settings  are  optimized  for  a  good  quality 
analog  output  signal.  If  any  one  of  axes  5-8  is  used  for  direct  PWM 
control  then  the  analog  output  signal  quality  should  be  compromised 
with a much lower PWM frequency, or not used at all. 
 
For Help with clock settings, use the Delta Tau Calculator: 
  
 
Analog Outputs Suggested M-Variables: 
// De-activate Motors 5-8 to write directly to the analog outputs 
I500,4,100=0 
 
 
; De-activate channels 5-8 
 
I569,4,100=816  
 
; Set Output Limit --User Input 
 
// Analog Outputs: 
M502->Y:$078102,8,16,S  
; Analog DAC Output (DAC5), Connector X9 
M602->Y:$07810A,8,16,S  
; Analog DAC Output (DAC6), Connector X10 
M702->Y:$078112,8,16,S  
; Analog DAC Output (DAC7), Connector X11 
M802->Y:$07811A,8,16,S  
; Analog DAC Output (DAC8), Connector X12 
 
Testing the Analog Outputs 
With the setting  of  I7100=816 (per the above  example), writing  directly to the assigned M-variable (i.e. 
Mxx02) should produce the following voltage output:  
 
Mxx02  Single Ended [VDC]  Differential [VDC] 
-816 
-10 
-20 
-408 
-5 
-10 
408 
+5 
+10 
816 
+10 
+20 
 
The  output  voltage  is  measured  between  AGND  and  DAC+  for  single-ended  operation  and  between 
DAC- and DAC+ for differential operation. 
 
Writing values greater than I7100 (i.e. 816) in Mx02 will saturate the output to 10, or 20 volts in single-
ended or differential mode respectively.  
 
 
Note 
MACRO connectivity provides more analog output options, e.g. ACC-
24M2A.