Delta Tau GEO BRICK DRIVE Manuel D’Utilisation

Page de 294
 Geo Brick Drive User Manual 
Macro Connectivity 
 242 
8.  If the Geo MACRO Drive has been configured prior to this setup, then it may have been assigned a 
station  number  and/or  may  have  some  enabled  nodes.  You  would  need  to  know  what  the  station 
number  is  in  order  to  perform  ASCII  communication,  or  which  nodes  are  enabled  in  order  to  issue 
MS commands. 
 
The  following  commands  can  then  be  issued  to  reset  the  Geo  MACRO  Drive(s)  back  to  its  factory 
default settings: 
 
MS$$$***15 will broadcast a global reset to stations associated with all enabled nodes 
 
MSSAV15 will broadcast a Save to stations associated with all enabled nodes 
 
MS$$$15 will broadcast a reset ($$$) to stations associated with all enabled nodes 
 
9.  Assuming that the Geo MACRO Drive(s) is or has been reset to factory default settings, we will now 
try to establish MACRO ASCII communication by issuing: 
 
MACSTA255 
This command  will  establish MACRO  ASCII (direct)  communication  with the first unassigned Geo 
MACRO Drive (if more than one is in the ring) starting from the OUT/Transmit fiber or RJ45 out of 
the Geo Brick Drive. 
 
10.  When  in  ASCII  mode,  download  from  the  editor  or  issue  the  following  commands  in  the  terminal 
window: 
I995 = $4080 
; MACRO IC ring configuration, typical slave setting 
I996 = $0F4003 ; Node activation (servo nodes 0, 1) –User Input 
 
11.  Issue a Control^T in the terminal window to exit ASCII mode communication 
 
Master Slave (MS) commands should now be available for nodes 0 and 1 (per this example). 
 
12.  Clock Settings   
The phase frequency should be set the same as the master’s. Set the following:  
MS0, I992 = Value of I7000 (or I6800) 
; Max Phase Clock 
MS0, I997 = Value of I7001 (or I6801) 
; Phase Clock Divider 
 
 
  
13.  Ring Check Error 
Enabling the ring check error function on the Geo MACRO drive requires computing and setting the 
following parameters: 
MS0,I8 
-> I80*(I6802+1) 
MS0,I9  
-> I81*(I6802+1)*(I8+1) 
MS0,I10 
-> I82*(I6802+1)*(I8+1) 
 
Where I8, I80, I81, I82, and I6802 are masters’ parameters. 
 
14.  Station Number 
The station number is used for ASCII communication. 
MS0, I11 = 1 
; Assign Station Number #1 –User Input 
 
15.  Issue MSSAV0 followed by MS$$$0 to maintain changes on the Geo MACRO Drive.