D1: AMP STATUS
The Turbo Clipper Drive utilizes a scrolling single-digit 7-segment display to exhibit faults to the
outside world. When control and DC bus power are applied, the Drive will display a solid dot
indicating that the software and hardware are running normally.
outside world. When control and DC bus power are applied, the Drive will display a solid dot
indicating that the software and hardware are running normally.
Error Codes
Display Description
Global Faults
Under Voltage Fault:
Indicates that the bus voltage is not present or less than 12Volts
Indicates that the bus voltage is not present or less than 12Volts
Over Voltage Fault:
Indicates that the bus voltage has exceeded 60Volts
Indicates that the bus voltage has exceeded 60Volts
Over Temperature Fault:
Indicates that the Board has exceeded 65°C
Indicates that the Board has exceeded 65°C
Axis n Faults (n=1 thru 4)
n
Axis n Over load Fault:
Indicates that the current rating (5/15A) of the drive has been exceeded
Indicates that the current rating (5/15A) of the drive has been exceeded
n
Axis n Over Current Fault:
Indicates that the peak current value has exceeded the permissible limit(20Amps)
Indicates that the peak current value has exceeded the permissible limit(20Amps)