Command name
Command
Byte
Number of
Parameters
in
Command
Parameters
Parameters
in
Response
AD
C
DA
C
DDC
MC
lk
RS_REF_MODES
77
2
first parameter is terminator (AES)
0 = unterminated
1 = terminated
second is reference mode
1 = ref out is internal
0 = pass through
0 = unterminated
1 = terminated
second is reference mode
1 = ref out is internal
0 = pass through
0
X X
X
RS_OVLD_LEV
87
1
Overload threshold, format X
0
X
RS_VOL
111
1
Digital volume control, format X
0
X X
RS_PHASE
112
1
Phase:
0 = None inverted
1 = Both inverted
2 = left inverted
3 = right inverted
0 = None inverted
1 = Both inverted
2 = left inverted
3 = right inverted
0
X X
RS_REF_MODE
114
1
Select reference input to clock from:
0 = AES1
1 = AES2
2 = SDIF-2 Clock (word clock)
3 = SPDIF1 or AES3
4 = SPDIF2 or AES4
5 = SPDIF3
0 = AES1
1 = AES2
2 = SDIF-2 Clock (word clock)
3 = SPDIF1 or AES3
4 = SPDIF2 or AES4
5 = SPDIF3
0
X X
RS_DSD_MODE
119
1
0 = DSD Off
1 = DSD (SDIF)
2 = 4-wire DSD
1 = DSD (SDIF)
2 = 4-wire DSD
Echos
message
X X X
RS_BAUD_RATE
141
1
Global command
None
X X X X
REQUEST_DSD_MODE
142
0
response -> DSD mode
Yes
REQUEST_FREQUENCY
143
0
response -> Frequency of unit
Yes
Table 11 – RS-232 Command Set
Format X – the level set number is –0.1dB times the 16 bit (positive integer)
used. So, for example, 260 would set –26dB below full scale for generator
amplitude.
used. So, for example, 260 would set –26dB below full scale for generator
amplitude.