BENDIX BW1892 Fascicule

Page de 2

SD-03-2205
DESCRIPTION
The Bendix
®
 SC-3
 in-line single check valve is a device 
placed in an air line to allow air flow in one direction only 
and to prevent flow of air in the reverse direction.
The two types of SC-3
 in-line single check valves are:
1. The wafer-style type (Figure 2).
2. The ball type (Figure 3).
An arrow indicating the direction of air flow is found on the 
body of the valve.
OPERATION
Air  flow  in  the  normal  direction  moves  the  check  valve 
from  its  seat,  and  the  flow  is  unobstructed.  Flow  in  the 
reverse direction is prevented by the seating of the ball or 
wafer-type disc, which is caused by a drop in up-stream 
air pressure and assisted by the spring.
PREVENTATIVE MAINTENANCE
Important:  Review  the  Bendix  Warranty  Policy  before 
performing  any  intrusive  maintenance  procedures. A 
warranty  may  be  voided  if  intrusive  maintenance  is 
performed during the warranty period.
No  two  vehicles  operate  under  identical  conditions;  as 
a result, maintenance intervals may vary. Experience is 
a  valuable  guide  in  determining  the  best  maintenance 
interval for air brake system components. At a minimum, 
the SC-3
 valve should be inspected every 6 months or 
1500 operating hours, whichever comes first, for proper 
operation. Should the SC-3
 valve not meet the elements 
of  the  operational  tests  noted  in  this  document,  further 
investigation and service of the valve may be required. 
Replace  any  check  valves  leaking  or  showing  signs  of 
wear or deterioration.
Bendix
®
 SC-3
 In-Line Single Check Valves
FIGURE 1 - 
SC-3
 Single CheCk valveS
outlet
inlet
spring
outlet
ball
FIGURE 3 - 
SC-3
 angle CheCk valve: ball type
(exterior and CroSS-SeCtional viewS)
FIGURE 2 - 
SC-3
 Single CheCk valve: wafer-type
(exterior and CroSS-SeCtional viewS)
(one sc-3
 
valve model 
features 
this 1/16” 
pipe plug)
inlet
inlet
outlet
outlet
spring
wafer-type 
check valve