BENDIX BW1760 Manuel D’Utilisation

Page de 8
1
 SD-03-3656
Bendix
®
 TP-3DC
 Tractor Protection Valve with Double Check
FIGURE 1 - TP-3DC
 TRACTOR PROTECTION VALVE WITH DOUBLE CHECK
AUXILIARY SUPPLY 
1/4" -18 NPT
DATE CODE 
STAMPED HERE
TRACTOR SUPPLY 
1/4"-18 NPT
TRACTOR CONTROL 
(PRIMARY) 3/8"-18 NPT
LABEL WITH
TP-3DC
 VALVE
O.E. PC. NO. HERE
TRAILER CONTROL 
1/2"-14 NPT
QR-L
 VALVE FACTORY 
INSTALLED ON SOME
TP-3DC
 VALVE MODELS
1/2"-14 NPT
1/2"-14 NPT
TRACTOR 
CONTROL 
(SECONDARY) 
3/8"-18 NPT
STOP LIGHT
SWITCH
1/4"-18 NPT
TRAILER SUPPLY 
1/2"-14 NPT
DESCRIPTION
The tractor protection valve system protects tractor air 
brakes during trailer breakaway and/or when severe air 
leakage develops in the tractor or trailer. This function is 
required by law.
In normal use the tractor protection valve is used to shut off 
the trailer control line before disconnecting the tractor from 
the trailer. It is usually mounted at the rear of the tractor 
cab, and it is used in conjunction with a dash-mounted 
control valve.
The TP-3DC
 valve integrates tractor protection and double 
check valve functions. It also has an integral single check 
valve that prevents trapping of air in the trailer control line. 
This prevents service and spring brake compounding, and 
it avoids a trailer roll away situation if the trailer is parked 
with the air applied.
A stoplight switch port allows direct stoplight installation, 
and the auxiliary supply port, when connected to the 
BP-R1
 control port, eliminates a tee in the tractor 
supply line. Also, a QR-L
 valve can be factory installed 
in the trailer control and/or supply port to meet timing 
requirements.
Port 
Embossed I.D.  Thread Size
Tractor Supply 
TRAC SUP 
1/4"-18 NPT
Auxiliary Supply 
AUX SUP 
1/4"-18 NPT
Tractor Control (Primary) 
TRACT CONT 
3/8"-18 NPT
Tractor Control (Secondary)  TRAC CONT 
3/8"-18 NPT
Stop Light Switch 
STP LT SW 
1/4"-18 NPT
Trailer Supply 
TRLR SUP 
1/2"-14 NPT
Trailer Control 
TRLR CNTL  
1/2"-14 NPT
Weight: 1.5 lbs.
Material: Die-cast aluminum
Operating pressure: 150 psi maximum
Operating temperature: -40° to 200° F
Figure 1 shows the TP-3DC
 valve with its port designations, 
O.E. piece number, and date code identifi cations.
Figure 2 is a sectional view of the TP-3DC
 valve, and 
Figure 3 presents the TP-3DC
 valve in a partial air brake 
system schematic.