Bacharach Hi Flow Sampler Manuel Du Propriétaire

Page de 72
Hi Flow Sampler 
Operation 
Instruction 0055-9017 
15
3.8.1 Basic 
Main 
Screen 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Date and Time: Date displayed as 
mm/dd/yy, while time is displayed in a 12-
hour format. The date and time are set per 
Section 5.8. 
Btry(V): Battery voltage 
Flow(lpm): Sample flow rate in either 
liters/min or cu.ft./min. 
Back(%): Measured background gas level in 
either percent-by-volume or ppm  
Leak(%): Measured natural gas leak 
concentration at the current sample flow rate 
in either percent-by-volume or ppm  
Leak(lpm): Calculated leak rate in either 
liters/min or cu.ft./min.* 
Speed(LO<––––|>HI): Blower speed indicator.  
Start / Stop: Select to Start and Stop a test**  
Menu: Select to display the first of several 
submenus (refer to Section 3.9)** 
: GPS (Global Positioning System) icon 
appears when instrument detects that a GPS 
receiver is connected to the unit’s GPS port 
: Barcode icon appears when the instrument 
detects that a barcode reader wand is 
connected to the unit’s SCANNER port 
: Battery status icon (refer to Section 3.10) 
[0001]
Current Test ID number 
(A)
or (M): Automatic or Manual mode (refer to 
Section 3.14) 
S--
: Standby 
-1-
: Measurement #1 (maximum flow rate) 
--2
: Measurement #2 (reduced flow rate) 
Message Line: Various messages appear 
during operation describing the current 
function being performed, or errors that have 
occurred (refer to Section 3.19) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
*  “Not Avail.” is displayed when a value cannot be calculated from available information. 
**  Selections are made by using the  keys to highlight the desired function, and then 
pressing the I/Okey to activate that function.