Bacharach Hi Flow Sampler Manuel Du Propriétaire

Page de 72
Introduction 
Hi Flow Sampler 
 
Instruction 0055-9017 
the range of 0.05 to 100% gas by volume. A second identical 
combustibles sensor channel measures the background CH
4
 level within 
the vicinity of the leaking component. The final element in the sampling 
system is a blower that exhausts the gas sample back into the 
atmosphere away from the sampling area.  
 
The measured flow rate and the measured CH
4
 levels (both leak and 
background levels) are used to calculate the leak rate of the component 
being tested, with all measured and calculated values being displayed on 
the hand-held control unit. 
 
 
1.2 Material 
Supplied 
 
  High Flow Sampler Unit 
  Backpack 
  6 Foot, 1.5 Inch Hose Assembly 
  Battery Pack (Qty. 2) 
  Battery Charger w/ Power Supply 
  Control Unit with LCD and 4-button keypad 
  Assortment of Attachments (for complete capture of the gas leak) 
 
Flange Strap 34", 80", and 137" 
 
Capture Bag 36" x 36" 
 
Beveled Nozzle 6.5" and 24" 
 
Bag Nozzle w/ box of disposable bags 
 
Bellows Tool 
 
Claw Tool 
 
3-Port Background Gas Sampler 
 
 
1.3 
Why Use the Hi Flow Sampler? 
 
  Allows ranking of gas leaks in leak-rate order 
  Allows users to determine if the potential savings in lost gas by 
repairing a leak 
  Allows users to determine payback periods for particularly 
expensive repairs 
  Allows more cost-effective use of your maintenance budget 
  Identifies problem areas 
  Determines baseline leakage conditions 
  Provides permanent record of leakage and repair 
  Greenhouse gas credits 
  Pays for itself in recovered gas