B&B Electronics Asynchronous to Synchronous Converter 2010 Manuel D’Utilisation

Page de 12
2010AS3297 Manual
5
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350
PH (815) 433-5100 -- FAX (815) 434-7094
 
Switch SW1-3: Extended Signaling Rate (ESR)
The setting for switch 1-3 determines the range of variability the Model
2010 looks for in asynchronous data rates (i.e., the actual variance from a
given frequency level the Model 2010 will tolerate).
SW 1-3
Off
-2.5% to +1%
On
-2.5% to +2.3%
Switch SW1-4: Not Used