6.1.5 
Maximum Security Arming 
Maximum security arming is used when no one is still in the building, all zones are to be armed, an exit delay is 
in effect, but no entry delay is in effect so an alarm 
does occur upon entry.  
The green Status LED must be lit and, if using a text keypad, “Ready to Arm” must be displayed. If the green 
LED is not on or the keypad displays “Not Ready,” you must use other methods to arm the system (refer to Section 
6.2.2 Force Arming
 on page 13 or Section 6.2.3 Zone Bypass on page 14). 
 
Table 7:  Maximum Security Arming 
 
 
 
 
Equipment  
Command Sequence 
What Happens 
What To Do 
Text Keypad LED 
Keypad 
[PIN][No Entry][On] 
•  The red Armed LED flashes. 
•  “Armed Instant” is displayed. * 
•  “Exit Now” is displayed during the exit-
delay period. * 
•  A single beep sounds. 
•  The red Armed LED lights steady when 
the exit-delay period ends. 
•  All zones are armed. 
•  Exit during the exit-delay 
period. 
•  Violating any zone after the 
exit-delay period ends 
triggers an instant alarm. 
RF3341 Keypad 
[PIN][#][5] 
•  The LED flashes indicating a signal was 
sent to your security system. 
•  All zones are armed. 
 •  Exit during the exit-delay 
period. 
•  Violating any zone after the 
exit-delay period ends 
triggers an instant alarm. 
RF3332/RF3332E, 
RF3334/RF3334E 
Not applicable 
* Text Keypad only