Bosch Appliances Home Security System D9412GV2 Manuel D’Utilisation

Page de 74
D9412GV2/D7412GV2 | Operation and Installation Guide | 5.0  Power Supply 
 
24 
Bosch Security Systems, Inc. | 5/05 | F01U003641B 
 
Table 8: 
Charging Status and Low Battery LEDs 
 
LED 
Type 
Color State 
Action 
Charging Status LED 
Yellow 
 
Shows the changing status of the battery. Refer to Figure 6  on  
page 23 for location. 
 
Yellow 
Off 
Battery is fully charged. 
If the battery is missing, shorted, or reversed, the Charging Status 
LED is off, but the red Low Battery LED is flashing. 
 
Yellow 
On 
Battery float charge is below 13.8 VDC. If AC is present, the battery 
is charging.  
Indicates the combined current draw from all outputs exceeds 1.4 A. 
This is normal under alarm conditions for non-fire systems with sirens 
or bells drawing more than 1.4 A. If the LED lights regularly for 
extended periods or does not go out, check the current draw for 
devices connected to the power outputs. Refer to Section 6.0 
Power Outputs 
on page 25 for instructions. 
 
Yellow 
Flash once per 
minute 
System is checking the battery. 
Low Battery LED 
Red 
 
Shows the condition of the battery. Refer to Figure 6  on page 23 for 
location. 
 
Red 
Off 
Battery is fully charged. 
 
Red 
On 
Battery voltage dropped to between 12.0 VDC and 11.8 VDC.  
LED turns off when voltage reaches 13.7 VDC. 
 Red 
 
Flash 
(same as green 
LED) 
Green LED is Operation Monitor LED. 
Battery is missing or shorted.