Bosch 2000 Manuel D’Utilisation

Page de 72
2000 Series | Program Entry Guide | 4.0 
Receiver 
EN | 19 
 
 
Bosch Security Systems | 7/05 | 35114F 
 
3 Non-Fire Group 
Default: 
0
 
Selection:  0 to 9, B to F
 
1 to 8 
Non-Fire alarm from Points 1 to 24.
 
9 or 0 
Non-Fire alarm from key A, B, or C. 
Refer to Section 
7.0
 ABC Keys. 
There are no Pulse Format versions of 
the Modem II Alarm recent Close, 
Alarm Cross Point, or Exit Alarm 
Reports. All occur as Alarm
 
Reports. 
The Cross Point feature creates two 
point alarms. Refer to Section 11.0 Point 
Codes.
 
4 Pt Trbl Group 
Default: 
0
 
Selection:  0 to 9, B to F
 
1 to 8 
Trouble, Missing, Bypass, or Swinger 
Bypass Reports from Fire and Non-Fire 
points combined. 
Multiple trouble conditions can create 
duplicate Trouble Reports. For 
example, a point can send a trouble for 
a open sensor loop, then a trouble for 
missing.
 
5 Restoral Group 
Default: 
0
 
Selection:  0 to 9, B to F
 
1 to 8 
Restoral on points 1 to 24, Fire and 
Non-Fire combined.
 
6 Closing Group 
Default: 
0
 
Selection:  0 to 9, B to F
 
Closing Report when a passcode is not 
required to turn system on (refer to 
Passcode
 
Rquired
 prompt in Section 
15.0 Passcodes) or a keyswitch is used.
 
1 to 8 
Closing Report with User ID for users 1 
to 8. 
 
7 Opening Group 
Default: 
0
 
Selection:  0 to 9, B to F
 
Opening Report when keyswitch is 
used, or Part On No Delay, or Part On 
with delay.
 
1 to 8 
Opening Report with User ID for users 
1 to 8. 
8 Cancel Group 
Default: 
0
 
Selection:  0 to 9, B to F
 
Cancel Report when keyswitch is used. 
1 to 8 
Cancel Report with User ID for users 1 
to 8. 
9 Sys Trbl Group 
Default: 
0
 
Selection:  0 to 9, B to F
 
Reports an unsuccessful attempt to connect a 
remote programmer.
 
2  
 
Reports an unsuccessful attempt to connect a 
remote programmer. 
The system automatically reset. Call Bosch 
Security Systems if reports persist. 
4 Not 
used. 
5 Not 
used. 
Reports missing battery. 
Reports low battery. 
No AC power to system. Control panel is 
running on battery. 
Communication Failure event for Phone 1. 
Communication Failure event for Phone 2. 
RF tamper (points or receiver). 
RF low battery. 
RF receiver 7 trouble. 
RF receiver 8 trouble.