BENDIX SD-08-2433 Manuel D’Utilisation

Page de 16
14
BENDIX
®
AD-9si
 AIR DRYER
TROUBLESHOOTING CHART
SYMPTOM
CAUSE
REMEDY
2.  Water in vehicle reservoirs. A.  Maximum air dryer inlet temperature is 
exceeded due to improper discharge 
line length. 
A.  Check for excessive carbon build-up in compressor discharge 
line.  Replace if required.  Make certain that discharge line 
length is at least 6 ft. Increase discharge line length and/or 
diameter to reduce air dryer inlet temperature.
B.  Ambient temperature exceeds 125°F. B.  Relocate the air dryer away from excessive heat source.
C.  Air  system  charged  from  outside 
air source (outside air not passing 
through air dryer).  
C.  If system must have outside air fill provision, outside air should 
pass through the air dryer. 
D.  Excessive air usage - Air dryer not 
compatible with vehicle air system 
requirement  (improper  air  dryer/
vehicle application).
D.  Refer to the 
Bendix
®
 Air Dryer Application Guideline (BW2600) 
for proper application of the Bendix
®
 AD-9si
 air dryer.  An 
extended purge reservoir may be added for higher air usage 
vehicles, such as city buses and construction vehicles.
  If the vehicle is equipped with high air usage accessories 
such as trailer pump-off systems or central tire inflation, the 
air for these accessories must by-pass the air dryer.
E.  Desiccant requires replacement. 
E.  Replace desiccant cartridge assembly.  See 
Bendix Air Dryer 
Application Guideline (BW2600) for recommended service 
intervals.
F.  Air dryer not purging. 
F.  Refer to Symptom 6.
G.  Purge (air exhaust) time insufficient 
due to excessive system leakage. 
G.  Refer to Symptom 1.
3.  Safety valve on air dryer 
“popping off” or exhausting 
air.  
A.  Safety valve setting too low (<150 psi). A.  Replace safety valve.
B.  System pressure too high (>135 psi). B.  Test with accurate gauge. Replace the governor cartridge if 
necessary.
C.  Excessive pressure pulsations from 
compressor. (Typical single cylinder 
type).  
C.  Increase the volume in the discharge line. This can be 
accomplished by adding a 90 cubic inch (or larger) reservoir 
between the compressor and the AD-9si air dryer.
4.  Constant exhaust of air at air 
dryer purge valve exhaust 
or  unable  to  build  system 
pressure. (Charge mode.)
A.  Air  dryer  purge  valve  leaking 
excessively.
A.  With compressor loaded, apply soap solution on purge valve 
exhaust, to test for excessive leakage. Repair or replace 
purge valve as necessary.
B.  Purge valve frozen open - faulty heater 
and thermostat, wiring, blown fuse.  
B.  Refer to paragraph 5 of the
 Operation and Leakage Tests for 
heater and thermostat test.
C.  Defective AD-9si
 air dryer delivery 
check valve. 
C.  Refer to Symptom 1, Remedy B.
D.  Leaking turbo cut-off valve.
D.  Repair or replace purge valve assembly.
E.  Defective governor. 
E.  Check the governor at both “cut-in” and “cut-out” positions 
for  proper pressures and excessive leakage at the exhaust. 
F.  Leaking purge valve control piston 
seals. 
F.  Repair or replace purge valve assembly.