Installation 
 
 
Counter Model 
Counter mounted units must be mounted on a level surface that can support the weight of the unit and it’s 
contents. Use a carpenter’s level to level the unit.  
 
These units are to be sealed to the counter if required by local health codes. Seal the perimeter of the 
units to the counter using a silicone-type sealant (Dow Corning RTV #732 or equivalent).  
Caster Model 
Caster mounted units must be moved to a permanent location and the two swivel casters locked before 
using. 
Wiring 
 
 
Electrocution, equipment failure or property damage could result if an unlicensed 
electrician performs the electrical installation. Ensure that a licensed electrician 
perform the electrical installation in accordance with local codes, or in the absence 
of local codes, with the National Electrical Code, ANSI NFPA 70-20XX. 
 
This unit, when installed by an authorized BKI service agent, must be wired for use in accordance with all 
applicable local, state, and federal codes. For specific electrical requirements and connections refer to the 
wiring diagram attached to the unit or provided in the Service Manual. 
Initial Setup and Adjustment 
Follow the procedure below to setup and adjust the unit for proper operation. 
 
1.  Connect the unit power cord to a receptacle that supplies power matching that specified on the 
unit rating plate. 
 
2.  Place the POWER ON/OFF circuit breaker in the ON position. 
 
3.  Let the unit preheat for 30 minutes. 
 
4.  Measure and adjust the temperature as necessary to achieve an initial temperature between  
190° F and 200° F. Use a surface temperature thermometer to measure this temperature (DO 
NOT USE A MEAT THERMOMETER). Additional adjustments may be necessary once the 
product is placed on the shelves. If so, refer to the section entitled Temperature Adjustment on 
page 4. 
 
5.  Place the POWER ON/OFF circuit breaker in the OFF position.