Configuring a Hot Spare
If you have 3 drives in a RAID 5 array, or 2 drives in a RAID 1 array, then you can configure another drive as a hot spare. If
one of the drives in the array fails, the TeraStation will switch over to the hot spare immediately.
1
2
3
Note:
If a hot spare is configured, click [Set to normal disk] to change the hot spare to a normal disk.
The [Confirm Operation] screen will appear. Enter the number shown in the [Confirmation Number] field within
4
60 seconds and click [Apply].
Follow the instructions displayed on the screen.
5
You have now configured a hot spare.
Note:
All data in the hot spare drive will be deleted when it is configured as a hot spare and again when it changes over from a
All data in the hot spare drive will be deleted when it is configured as a hot spare and again when it changes over from a
spare to a drive in the array.
Choose a RAID 5 or RAID1 array.
Click [Set to spare-disk].