DESCRIPTION 
 
NAMEPLATE 
 
 
FIRE SUPPRESSION    
AGENT TANK (1.5 gal.) 
 
ADJUSTABLE (FRONT) 
LEG  
 
RIGID (REAR) CASTER 
 
 
MANUAL PULL STATION  
 
 
FUSIBLE LINKS 
 
 
LOWER REAR ACCESS 
PANEL 
 
DISCHARGE NOZZLE 
 
GREASE BAFFLE  
 
PRE-FILTER ASSEMBLY  
 
 
 
HEPA/CHARCOAL FILTER 
PACK 
 
GREASE COLLECTOR  
 
VENTILATOR EXHAUST 
DUCT 
 
STATUS INDICATOR 
 
 
POWER CORD 
 
POWER FUSES 
 
 
POWER CONTACTOR  
 
BUILDING FIRE ALARM       
RELAY 
 
GROUND LUG 
 
INTERLOCK TERMINAL 
 
 
FILTER INTERLOCK 
SWITCHES 
 
VENTILATOR FAN 
COMMENT 
 
Lists Manufacturer, Model and Serial Number information. 
Also lists electrical specifications. 
 
Container for Ansulex™ Low-pH liquid fire suppression liquid.  
 
 
Allows the unit to be leveled. 
 
 
Allows the unit to be easily positioned by lifting the front of the 
unit slightly. 
 
Provides a means of manual activation of the  fire suppression 
system.  PULL ONLY IN CASE OF FIRE! 
 
Automatically activates fire suppression system in the event of 
fire on the griddle. 
 
Allows access to Ansul® fire suppression agent tank (a6) and 
controls also access to main power contactor (41). 
 
Fire suppression media discharges here (2 places). 
 
Extracts and drains most grease and moisture from the air flow. 
 
Comprises the PRE-FILTER FRAME and a replaceable 
PRE-FILTER.  Stops larger particles of grease from  reaching 
the FILTER PACK for reduced maintenance costs. 
 
Stops most grease and smoke particles.   Also assists in some 
cooking odor removal. 
 
Collects grease/moisture drained from filter bank. 
 
Exit point for ventilator airflow - on top left rear of unit. 
DO NOT BLOCK 
 
Displays status of fire suppression system (COCKED - FIRED
If FIRED, a buzzer will sound continuously. 
 
6’ cord and cap.   Plug for NEMA 15-60R (receptacle by user). 
 
Provides over-current protection for convection oven section. 
 
Energizes griddle only while ventilator section is  sensed as              
operational. 
 
Reports fire alarm condition to building fire management        
system. 
 
Ground wire of power cord connects here. 
 
Provides connection for shut-down control by building fire                
management system. 
 
Proper installation of grease baffle and filter pack close these 
switches in ventilator sensor circuit. 
 
Provides air movement for ventilation. 
FEATURES & OPERATING CONTROLS (continued) 
VENTILATOR SECTION 
509 3059
36 O
p
M
 W
V
OC-G
136