Bell Automobile Electronics BSX 16 Manuel D’Utilisation

Page de 32
BSX Isolated Audio Entry System 
PD-142 Issue 1 
Installation and Operating Manual 
Page 10 of 32 
 
Power Supply Capability/Limitations 
 
Type  Rating 
Description 
Cab3 
2A Continuous 
3A Peak 
Used on 1 door systems with either fail secure 
or fail safe lock releases up to 1A. 
Sufficient spare capacity to supply a 200 coded 
access controller and/or a Pax1 proximity reader. 
Cab5 
4A Continuous 
5A Peak 
Used on 2 door systems with either fail secure 
or fail safe lock releases up to 1A. 
Sufficient spare capacity to supply a 200 coded 
access controller and/or a Pax1 proximity reader. 
N.B.  No extra equipment should be powered without first consulting the technical department. 
 
Battery Backup 
Space  is provided  in the cabinet  to fit a  standard 7AH battery to the  power supply  (both 
Cab3 and Cab5 models) to provide battery backup in case of mains supply failure. 
Backup  time  depends  largely  upon  the  idle  power  usage  of  the  system  which  can  vary 
widely according to the following factors: - lock type, the number and type of phones, door 
status indicator (on or off), the number of door panels and any additional equipment which 
may be fitted. 
The longest backup times are achievable with fail secure lock releases as these only take 
current while unlocking the door; backup times exceeding 8 hours for a single door and 6 
hours for a two door system are possible for moderate usage, reducing if system usage is 
particularly high. 
The use of fail safe lock releases will require individual calculation for back up time.  For 
instance, a 2 door system with 1A maglocks  should not be expected to last much longer 
than 2 hours. 
Cab3 and Cab5 supplies do not support the use of batteries larger than 7AH.