Behringer Stereo System CX3400 Manuel D’Utilisation

Page de 16
15
SUPER-X PRO CX3400 User Manual
5.  Specifications
Input
Connectors  
XLR
Type   
 
Electronically servo-balanced, RF filtered
Impedance 
 
Balanced >50 kOhms, unbalanced >25 kOhms
Max. Input level   
+22 dBu typical, balanced or unbalanced
CMRR  
 
>40 dB, typically >55 dB at 1 kHz
Output
Connectors  
XLR
Type   
 
Electronically servo-balanced, RF filtered
Impedance 
 
Balanced 60 Ohms, unbalanced 30 Ohms
Max. Output Level 
+20 dBm balanced/unbalanced
Performance
Bandwidth 
 
20 Hz to 20 kHz, +0/-0.5 dB
Frequency Response 
<5 Hz to >90 kHz, +0/-3 dB
Signal to Noise   
Ref.: +4 dBu, 20 Hz to 20 kHz, unweighted
  
 
 
Stereo Mode: 
Mono Mode: 
Low Output 
 
>93 dBu   
>93 dBu
Low-Mid 
Output 
   >94 
dBu
Mid Output 
 
>95 dBu
High-Mid 
Output 
   >94 
dBu
High Output 
 
>90 dBu   
>88 dBu
Dynamic Range   
>106 dB, unweighted
THD & Noise 
 
Limiter Off: 
Limiter On: 
 
  <0.04% 
 <0.5
Interchannel Crosstalk 
High to Low: 
<93 dB 
 
 
 
High to Mid: 
<94 dBu 
 
 
 
Mid to Low: 
<95 dBu 
 
 
 
High to High-Mid:  
<95 dBu 
 
 
 
High-Mid to Low-Mid:  <95 dBu 
 
 
 
Low-Mid to Low:  
<92 dBu
Crossover
Filter Type 
 
Linkwitz-Riley, 24 dB/Octave, state-variable
Stereo Mode Frequencies 
x1   x10
Low/High 
 
44 to 930 Hz 
440 Hz to 9.3 kHz
Low/Mid 
 
44 to 930 Hz  
440 Hz to 9.3 kHz
Mid/High 
 
440 Hz to 9.3 kHz
Mono Mode Frequencies 
x1   x10
Low/Low-Mid   
44 to 930 Hz 
440 Hz to 9.3 kHz
Low-Mid/High-Mid 
440 Hz to 9.3 kHz
High-Mid/High   
440 Hz to 9.3 kHz
Function Switches
Front Panel
Low Cut 
 
Activates 25 Hz Butterworth, 
 
 
 
12 dB/Octave high-pass filter
Mute   
 
Mutes the individual output
Phase Invert 
 
Inverts the phase at the individual output
CD Horn 
 
Corrects CD horn frequency response 
 
 
 
above 3.5 kHz
Limiter 
 
Activates the limiter function for all outputs
Rear Panel
Xover Frequency   
Multiplies crossover frequency range by 10
Mode  
 
Selects stereo/mono and 2/3/4-way operation
LF Sum 
 
Selects normal stereo or mono-summed 
 
 
 
low frequency operation 
 
 
 
ON=Channel 1 + 6dB louder / Channel 2: 
 
 
 
the same as before
Controls
Input  
 
Controls the input gain (+/-12 dB)
Xover Frequency   
Controls the crossover frequency
Delay  
 
Controls the delay at the low output 
 
 
 
(0 to 2 msec.)
Gain   
 
Controls the output gain (+/-6 dB)
Threshold 
 
Controls the threshold of the limiter 
 
 
 
(–6 dB to OFF)
Power Supply
Mains Voltages
USA/Canada 
 
120 V~, 60 Hz
 U.K./Australia   
240 V~, 50 Hz
 Europe 
 
230 V~, 50 Hz
 General Export Model 
100 - 120 V~,  
 
 
 
200 - 240 V~, 
 
 
 
50 - 60 Hz
Power Consumption 
max. 22 W
Fuse   
 
100 - 120 V~: T  630 mA  H 
 
 
 
200 - 240 V~: T  315 mA  H
Mains Connection 
Standard IEC receptacle
Physical
Dimensions 
 
1 ¾ x 19 x 8 ½" / 44.5 x 482.6 x 217 mm
Net Weight 
 
2.5 kg
Shipping Weight   
3.5 kg
BEHRINGER is constantly striving to maintain the highest professional standards. As a result of these efforts, 
modifications may be made from time to time to existing products without prior notice. Specifications and 
appearance may differ from those listed or illustrated.