Electrical Requirements
If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrical installer determine that 
the ground path and wire gauge are in accordance with local 
codes.
Do not use an extension cord.
Be sure that the electrical connection and wire size are adequate 
and in conformance with the National Electrical Code, ANSI/NFPA 
70-latest edition and all local codes and ordinances.
A copy of the above code standards can be obtained from: 
National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269.
WARNING: Improper connection of the equipment-grounding 
conductor can result in a risk of electric shock. Check with a 
qualified electrician or service technician if you are in doubt as to 
whether the appliance is properly grounded. Do not modify the 
power supply cord plug. If it will not fit the outlet, have a proper 
outlet installed by a qualified electrician.
Electrical Connection
To properly install your range, you must determine the type of 
electrical connection you will be using and follow the instructions 
provided for it here.
Range must be connected to the proper electrical voltage and 
frequency as specified on the model/serial number rating 
label. The model/serial number rating label is located on the 
bottom right front of the toe kick plate. Refer to the figures in 
the “Product Dimensions” section of the “Location 
Requirements” section.
This range is manufactured with the neutral terminal 
connected to the cabinet. Use a 3-wire, UL listed, 40- or 
50-amp power supply cord (pigtail) (see following Range 
Rating chart). If local codes do not permit ground through the 
neutral, use a 4-wire power supply cord rated at 250 volts, 
40 or 50 amps and investigated for use with ranges.
*The NEC calculated load is less than the total connected load 
listed on the model/serial number rating label.
**If connecting to a 50-amp circuit, use a 50-amp rated cord with 
kit. For 50-amp rated cord kits, use kits that specify use with a 
nominal 1
³⁄₈" (34.9 mm) diameter connection opening.
A circuit breaker is recommended.
The range can be connected directly to the circuit breaker box 
(or fused disconnect) through flexible or nonmetallic sheathed, 
copper or aluminum cable. See “Electrical Connection.”
Allow 2 to 3 ft (61.0 cm to 91.4 cm) of slack in the line so that 
the range can be moved if servicing is ever necessary.
A UL listed conduit connector must be provided at each end 
of the power supply cable (at the range and at the junction 
box).
Wire sizes and connections must conform with the rating of 
the range.
The wiring diagram is located on the back of the range or 
inside the storage drawer in a clear plastic bag.
If connecting to a 4-wire system:
This range is manufactured with the ground connected to the 
neutral by a link. The ground must be revised so the green ground 
wire of the 4-wire power supply cord is connected to the cabinet. 
See “Electrical Connection.”
Grounding through the neutral conductor is prohibited for new 
branch-circuit installations (1996 NEC); mobile homes; and 
recreational vehicles, or an area where local codes prohibit 
grounding through the neutral conductor.
When a 4-wire receptacle of NEMA Type 14-50R is used, a 
matching UL listed, 4-wire, 250-volt, 40- or 50-amp, range power 
supply cord (pigtail) must be used. This cord contains 4 copper 
conductors with ring terminals or open-end spade terminals with 
upturned ends, terminating in a NEMA Type 14-50P plug on the 
supply end. 
The fourth (grounding) conductor must be identified by a green or 
green/yellow cover and the neutral conductor by a white cover. 
Cord should be Type SRD or SRDT with a UL listed strain relief 
and be at least 4 ft (1.22 m) long.
The minimum conductor sized for the copper 4-wire power 
cord are:
40-amp circuit
2 No.-8 conductors
1 No.-10 white neutral
1 No.-8 green grounding
If connecting to a 3-wire system:
Local codes may permit the use of a UL listed, 3-wire, 250-volt, 
40- or 50-amp range power supply cord (pigtail). This cord 
contains 3 copper conductors with ring terminals or open-end 
spade terminals with upturned ends, terminating in a NEMA Type 
10-50P plug on the supply end. Connectors on the appliance end 
must be provided at the point the power supply cord enters the 
appliance. This uses a 3-wire receptacle of NEMA Type 10-50R.
Range Rating*
Specified Rating of 
Power Supply Cord Kit 
and Circuit Protection
120/240 Volts
120/208 Volts
Amps
8.8 - 16.5 KW
16.6 - 22.5 KW
7.8 - 12.5 KW
12.6 - 18.5 KW
40 or 50**
50
4-wire receptacle (14-50R)
3-wire receptacle (10-50R)