Whirlpool ACE082XR0 Manuel D’Utilisation

Page de 28
5
To test your power supply cord: 
1. Plug power supply cord into a grounded 3 prong outlet.
2. Press RESET.
3. Press TEST (listen for click; Reset button will trip and pop 
out).
4. Press and release RESET (listen for click; Reset button will 
latch and remain in). The power supply cord 
 
is ready for 
operation.
NOTES:
The Reset button must be pushed in for proper operation.
The power supply cord must be replaced if it fails to trip when 
the test button is pressed or fails to reset.
Do not use the power supply cord as an off/on switch. The 
power supply cord is designed as a protective device.
A damaged power supply cord must be replaced with a new 
power supply cord obtained from the product manufacturer 
and must not be repaired. 
The power supply cord contains no user serviceable parts. 
Opening the tamper-resistant case voids all warranty and 
performance claims.
INSTALLATION INSTRUCTIONS
Unpacking
Remove packaging materials
Remove and properly dispose of packaging materials.  
Remove tape and glue residue from surfaces before turning 
on the air conditioner. Rub a small amount of liquid dish soap 
over the adhesive with your fingers. Wipe with warm water 
and dry.
Do not use sharp instruments, rubbing alcohol, flammable 
fluids, or abrasive cleaners to remove tape or glue. These 
products can damage the surface of your air conditioner. 
Handle air conditioner gently.  
1. Remove air conditioner from carton and place on cardboard.
2. Remove shipping screw from side wall of cabinet.
3. Pull off control knobs (on some models).
4. Remove front panel from air conditioner and set aside.
5. Remove ground screw and ground wire from front of air 
conditioner base. Save ground screw.
 
6. Pull on handle to slide air conditioner out of cabinet. Place air 
conditioner on cardboard.
NOTE: Do not lift, push, pull or remove any expanded 
polystyrene (foam) from inside the air conditioner. It is not 
packing material.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, 
fire, or electrical shock.
WARNING
A. Shipping screw
WARNING
Excessive Weight Hazard
Use two or more people to move and install 
air conditioner.
Failure to do so can result in back or other injury.
A
A. Green ground wire
B. Ground screw
A. Handle
A
B
+
+
+
A