4. Install foam seal in the gap between air conditioner base and 
cabinet. Push foam seal in at the sides and trim any excess 
material.
5. Remove the 2 front panel screws from air conditioner base. 
6. Insert front tabs of front panel into top of cabinet and swing 
front into place. 
7. Attach bottom front of panel with front panel screws. Replace 
control knobs (on some models).
NOTE: Route power supply cord through notch in front panel.
8. Plug into a grounded 3 prong outlet.
9. Press RESET on the power supply cord plug.
AIR CONDITIONER USE
Operating your air conditioner properly helps you to obtain the 
best possible results. 
This section explains proper air conditioner operation.
IMPORTANT: 
If you turn off the air conditioner, wait at least 3 minutes 
before turning it back on. This prevents the air conditioner 
from blowing a fuse or tripping a circuit breaker.
Do not try to operate your air conditioner in the cooling mode 
when outside temperature is below 65°F (18°C). The inside 
evaporator coil will freeze up, and the air conditioner will not 
operate properly.
NOTE: In the event of a power failure, your air conditioner will 
operate at the previous settings when the power is restored.
Starting Your Air Conditioner
1. Remove clear protective film from front panel badge (on 
some models).
2. Set the Exhaust control. See “Exhaust Control (on some 
models)” later in this section.
3. Set the Fan Control to desired setting. See “Fan Control” for 
your particular model later in this section.
4. Turn the Thermostat control to a mid-setting. See 
“Thermostat” for your particular model later in this section.
A. Foam seal
A. Front panel screws
B. Power supply cord notch
A
A
B
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, 
fire, or electrical shock.
WARNING