Worth Data 5000 Manuel D’Utilisation

Page de 126
 
67 
 
DATA ID:  
 
The DATA ID field has 6 different functions, depending on what is entered at the prompt: 
 
 
Data Identifiers 
 
UPC/EAN Check Digit verification 
 
Table Access 
 
Display Date/Time 
 
Prevent Duplicate Entry 
 
Compare Data 
 
1.  Data Identifiers 
The  first  function  of  the  DATA  ID  field  is  to  specify  Data  Identifiers  for  the  data  entered  for  the  current  statement.    Data 
Identifiers
  are  commonly  used  by  the  Automotive  and  Retail  industries  and  are  used  to  make  sure  the  correct  type  of  data  is 
entered.  For example, to make sure the TriCoder only accepts data for this prompt that starts with 1A1, put 1A1 in the Data  ID 
field: 
DATA ID:  
1A1 
 
Data Identifiers can be up to 3 characters long and can be position specific.  To only accept data where the second character is 
“S”, put S in the second character position in the Data ID field: 
 
DATA ID:  _
S
(data is “space” “S” “space”) 
 
In this example, the data in positions 1 and 3 can be anything; but position 2 must be an “S”. 
 
2.  UPC/EAN Check digit verification for keyed-in data 
The second function of the Data ID field is to have the TriCoder verify the check digit on an UPC or EAN bar code when the data 
has be entered on the TriCoder keypad (not scanned).  This scenario happens often when bar codes are damaged or missing and 
the data has to be entered by hand.  To avoid errors when the data is keyed in, the TriCoder will calculate a check digit for the 
data and compare it to the check digit that  was keyed in.   If the two digits do not  match, the TriCoder generates the following 
error message: 
 
INVALID INPUT 
HIT ANY KEY_ 
 
To use this feature, enter the following characters at the DATA ID prompt: 
U10 - Use this to verify UPC 12 or 8 digit entries 
E10 - Use this to verify EAN 13 or 8 digit entries 
B10 - Use this to check for both UPC and EAN 13, 12 or 8 digit entries.  
 
UPC/EAN 2 and 5 digit supplements are not supported. 
 
3.  Table Access 
The TriCoder can access a downloaded table during data collection to help aid in the data collection process. Tables are lists of 
data  that  can  be  either  Validated  -  the  TriCoder  compares  the  scanned  or  keyed  data  to  see  if  it  exists  in  the  table  and  if  that 
number has been already entered, or data in the table can be placed on screen based on data  Lookup from the table - displaying 
other  fields  associated  with  that  record  e.g.  price,  quantity  on  hand,  description  etc…    The  TriCoder  has  room  for  1  Table  of 
1MB in size. 
 
Table Validation: 
Table  Validation  uses  data  records  that  consist  of  a  single  field.    The  user  enters  a  piece  of  data  into  the  TriCoder  and  the 
TriCoder checks the table to see if there is matching data. If so, the TriCoder writes the data to the data file and goes to the next 
program statement.  To use Table Validation enter the following characters at the DATA ID prompt: 
A1A
 
(validates data from table)  
 
Not only can the TriCoder validate the data exists in the Table, but it can also prevent the user from entering the same data twice 
by entering these characters at the DATA ID prompt: 
D1D