White Rodgers 36G22-254 36G Series Gas Valve Catalogue

Page de 1
36G, 36J SERIES
GAS VALVES
GAS BURNER
CONTROLS
PARTS AND ACCESSORIES 
See end of this section for parts and accessories
TECHNICAL HELP
Wiring Diagrams. . . . . . . . . . . . . . . . . . . . . .  See page 178
?
36J Series
PAGE 
178
36G, 36J SERIES GAS VALVES
The 36G, 36J is a Combination Gas Control Valve Designed for    
Use with Non-Piloted Intermittent Ignition Systems. The Control    
is Designed to Meet Today’s Maximum Capacity, Smaller Size
and High Efficiency Gas Systems
FEATURES
• Inlet and outlet screens.
• Quiet redundant.
• Built-in pressure tap.
• Quick-connect terminals (
1
/
4
).
SPECIFICATIONS
Ambient Temperature . . . . . . . . . . . . . . . .   -40 to 175°F
Maximum Pressure Rating . . . . . . . . . . . .  
1
/
2
 PSI (14.0” W.C.)
Capacity (1” P.D.). . . . . . . . . . . . . . . . . . .   Natural 140,000 Btu/Hr.
   
  L.P. 226,800 Btu/Hr.
Electrical Rating . . . . . . . . . . . . . . . . . . . .   Single stage 24V, 50 / 60Hz at .3A
   
  Two stage at .43A
Swing Radius . . . . . . . . . . . . . . . . . . . . . .  2.75”
Mounting. . . . . . . . . . . . . . . . . . . . . . . . . .   Any position
Agency . . . . . . . . . . . . . . . . . . . . . . . . . . .   C.S.A. approved
Valve
(Stages)
Pipe Size
1 Pressure Drop Capacity
Range of Regulation
BTU/HR
BTU/HR
Adjustment
Range
(Nat. IN. W.C.)
Adjustment
Range
(L.P. IN. W.C.)
Std. Gas
.64 Sp. Gr.
(1000 BTU/CU. FT.)
LP Gas
1.53 Sp. Gr.
(2500 BTU/FT.)
Std Gas
.64 Sp. Gr.
(1000 BTU/CU. FT.)
LP Gas
1.53 Sp. Gr.
(2500 BTU/FT.)
Single
1/2” x 1/2”NPT
140,000 BTU/HR
226,800 BTU/HR
40,000-210,000
60,000-340,000
2.5”-5.0”
7.0”-12.0”
Two
1/2” x 1/2”NPT
140,000 BTU/HR
226,800 BTU/HR
20,000 Low-   
210,000 High
32,000 Low- 
340,000 High
1.0”-4.0” Low 
2.0”-5.0” High
4.0”-10.0” Low
6.0”-12.0” High
Modulating 1/2” x 1/2”NPT
140,000 BTU/HR
226,800 BTU/HR
20,000 - 210,000 
32,600 - 340,000
0.40”-4.0” 
1.3”-11.5” 
Model
Number
Coil 
Voltage
Gas Type
Pipe
Size
Opening
Characteristic
Regulator
Setting
Regulator
Adjustment
Range
Convertible
Nat. / LP
LP
Conversion
Kit
Included
Flow
Direction
Reducer
Bushing
Kit
Filter 
Screen
Inlet 
Pressure 
Tap
Outlet
Pressure 
Tap
Internal
Wiring
See
Figure 
36G22-254 24 VAC Natural or
LP
1
/
2
 x 
1
/
2
Fast Opening
Single Stage
3.5”
Nat. 2.5”- 5.0”
L.P. 7.0”- 12.0”
Yes
No**
Str. Thru
No
Yes
Yes
Yes*
1
36J22-214 24 VAC Natural or
LP
1
/
2
 x 
1
/
2
Fast Opening
Single Stage
3.5”
Nat. 2.5”- 5.0”
L.P. 7.0”- 12.0”
Yes
Yes
Str. Thru
Yes
Yes
Yes
Yes
1
36J24-214 24 VAC Natural or
LP
1
/
2
 x 
1
/
2
Slow Opening
Single Stage
3.5”
Nat. 2.5”- 5.0”
L.P. 7.0”- 12.0”
Yes
Yes
Str. Thru
Yes
Yes
Yes
Yes
1
36J54-214 24 VAC Natural or
LP
1
/
2
 x 
1
/
2
Two-Stage
Fast Opening
LO 1.5”
HI 3.5”
Nat. 2.5”- 5.0”
L.P. 6.0”- 12.0”
Yes
Yes
Str. Thru
Yes
Yes
Yes
Yes*
36J55-214 24 VAC Natural or
LP
1
/
2
 x 
1
/
2
Two-Stage
Slow Opening
3.5”
Nat. 2.5”- 5.0”
L.P. 6.0”- 12.0”
Yes
Yes
Str. Thru
Yes
Yes
Yes
Yes*
2
36J24-614 24 VAC Natural or
LP
1
/
2
 x 
1
/
2
Single Stage
Slow Opening
3.5”
Nat. 2.5”- 5.0”
L.P. 7.0”- 12.0”
Yes
Yes
90
o
Bottom
Outlet
No
Yes
Yes
Yes*
2
36J55-614 24 VAC Natural or
LP
1
/
2
 x 
1
/
2
Two-Stage
Slow Opening
3.5”
Nat. 2.5”- 5.0”
L.P. 6.0”- 12.0”
Yes
Yes
90
o
Bottom
Outlet
No
Yes
Yes
Yes*
2
* To measure outlet pressure on valves, loosen outlet pressure tap screw one quarter turn and put manometer hose over the top of the outlet pressure tap.
** Use F92-0659 to convert to regulated L.P. gas
 Wiring diagrams – see page 178
www.white-rodgers.com
41
HEA
TING