INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation. 
Read and follow the instructions provided with any tools listed 
here.
Tools needed
Parts supplied
Check that all parts are included.
3 - 10-32 hex nuts (attached to terminal block)
3 - Terminal lugs 
Anti-tip bracket must be securely mounted to floor or wall. 
Thickness of flooring may require longer screws to anchor 
bracket to floor.
Parts needed
If using a power supply cord kit:
A UL listed power supply cord kit marked for use with ranges. 
The cord should be rated at 250 volts minimum, 40 amps or 
50 amps that is marked for use with nominal 1
³⁄₈" (3.5 cm) 
diameter connection opening and must end in ring terminals 
or open-end spade terminals with upturned ends.
A UL listed strain relief.
Check local codes. Check existing electrical supply. See the 
appropriate “Electrical Requirements” section.
It is recommended that all electrical connections be made by a 
licensed, qualified electrical installer.
Location Requirements
IMPORTANT: Observe all governing codes and ordinances. 
It is the installer’s responsibility to comply with installation 
clearances specified on the model/serial rating plate. The 
model/serial rating plate is located on the frame behind a top 
corner of the door or either side of the drawer.
To eliminate the risk of burns or fire by reaching over heated 
surface units, cabinet storage space located above the 
surface units should be avoided. If cabinet storage is to be 
provided, the risk can be reduced by installing a range hood 
that projects horizontally a minimum of 5" (12.7 cm) beyond 
the bottom of the cabinets.
Cabinet opening dimensions that are shown must be used. 
Given dimensions are minimum clearances.
The anti-tip bracket must be installed. To install the anti-tip 
bracket shipped with the range, see “Install Anti-Tip Bracket” 
section.
Grounded electrical supply is required. See the appropriate 
“Electrical Requirements” section.
IMPORTANT: To avoid damage to your cabinets, check with your 
builder or cabinet supplier to make sure that the materials used 
will not discolor, delaminate or sustain other damage. This oven 
has been designed in accordance with the requirements of UL 
and CSA International and complies with the maximum allowable 
wood cabinet temperatures of 194° (90°C).
Mobile Home - Additional Installation Requirements
The installation of this range must conform to the Manufactured 
Home Construction and Safety Standard, Title 24 CFR, Part 3280 
(formerly the Federal Standard for Mobile Home Construction 
and Safety, Title 24, HUD Part 280). When such standard is not 
applicable, use the Standard for Manufactured Home 
Installations, ANSI A225.1/NFPA 501A or local codes.
Mobile home installations require:
When this range is installed in a mobile home, it must be 
secured per the instructions in this document.
Four-wire power supply cord or cable must be used in a 
mobile home installation. The appliance wiring will need to be 
revised. See “Electrical Connection - U.S.A. Only” section.
Tape measure
Flat-blade screwdriver
Phillips screwdriver
Level
Hammer
Hand or electric drill
Wrench or pliers
Marker or pencil
Masking tape
¼" drive ratchet
¼" nut driver 
³⁄₈" and ⁵⁄₁₆" nut driver
¹⁄₈" (3.2 mm) drill bit (for 
wood floors)
Tin snips or large wire 
cutters (for cutting ground 
strap if necessary)
A. Anti-tip bracket
B. #12 x 1
⁵⁄₈
"
 screws (2)
A
B