Rosewill RGD-CT505 Manuel D’Utilisation

Page de 4
 
Alkaline Battery Charger
  RGD-CT505                                                                      User  Manual 
     
 
 
3
D)
    The Definition of LED Indicator 
◎  Power on : LED indicator shows green light. 
◎  Charging mode : LED indicator shows red light. 
◎  Charging completed mode : LED indicator will flash Green and Rd light for five times by 
turns, then LED indicator status is green. 
◎  New batteries and fully charged batteries : LED indicator will flash in green light for five 
times and then enter the standby mode. 
◎  Low voltage batteries below default setting or aged Batteries : LED indicator shows off 
◎  The LED indicator shows off or steady green when old or damaged batteries inserted to 
the charger.    In this case the charger won’t charge the damaged batteries, so please 
remove the batteries from the charger and dispose of at your nearest recycling 
point/center. 
◎  Batteries fall off (insert incorrect) : LED light flashes one time and turns off. 
◎  Overheat : LED indicator Green and Red light flashes by turns. 
 
 
E)  Caution 
◎  Please read through and follow the instruction and caution. 
◎  Alkaline Battery Charger is applicable to charge used Alkaline and NiMH batteries 
◎  DO NOT charge used Carbon-Zinc/NiCd Batteries or Old batteries that are not in use for 
long time.    This could result in overheat of batteries or leak of chemical substances and in 
turn damages to the charger.    The one-year warranty is not applicable to the above 
situation. 
◎  It is recommended to use the charger with quality alkaline batteries which are newly 
produced and discharged. DO NOT charges the giveaway batteries of lower quality that 
usually comes along with electronic devices. 
◎  Alkaline battery doesn’t have the memory function.    So it’s recommended for used 
alkaline batteries with a longer charging time than use time for a better effect. 
◎  It is recommended to charge used NiMH batteries twice consecutively (or around 8 hours) 
before use for a better effect. 
◎  DO NOT charge the deformed, damaged, rusted or leaked batteries with the charger. 
◎  Make sure the charger is in the standby mode before charging any used batteries to 
prevent insufficient charging time.    Otherwise, the problem can be solved by turning on 
the power again. 
◎  Low voltage batteries below default setting or aged Batteries : LED indicator shows off or 
steady green when old or damaged batteries inserted to the charger.    In this case the 
charger won’t charge the damaged batteries, so please remove the batteries from the 
charger and dispose of at your nearest recycling point/center. 
◎  It’s recommended to store used batteries in containers, to avoid mixing batteries altogether, 
and prevent contact between negative and positive poles of batteries.