Location and Mounting
The 
Unity 550
 is sized at 1RU, and may be mounted in a standard 19-inch equipment rack or set up for 
desktop operation. In either location, maintain a clean, dry environment for the
 Unity 550
.
Rack Mounting
The 
Unity 550
 unit should be installed in such a way that a half-inch clearance is allowed on each side 
and a quarter-inch on the top to ensure adequate air flow. Ensure that a hazardous condition is not 
produced by uneven loading, or by resting any unsupported equipment on a rack-mounted 
Unity 550
 
unit.
Parts for the 
Unity 550
 unit include 2 angle rack mount brackets and 4 rubber feet. For rack mounting, 
do 
not
 attach the rubber feet as they interfere with the rack mounting. 
1. Remove the 2 screws from the left and right sides of the unit. 
2. Insert the angle brackets into the left and right sides of the unit ensuring that the screw holes for 
the unit and brackets are aligned.
3. Secure the brackets by re-inserting the screws through the brackets and unit.
4. Install the unit onto the rack.
NOTE:
The front brackets must be secured to the rack. If the front brackets are left unsecured, the unit 
may shift forward and fall from the rack, and may result in personal injury and/or damage to the 
equipment. The internal temperature of the rack should not exceed 40
 o
 C.
Desktop Installation
Parts for the 
Unity 550
 unit include 2 angle rack mount brackets and 4 rubber feet. For desktop 
installation, do 
not
 attach the brackets.
1. Attach the 4 rubber feet onto the indented areas at the bottom of the unit.
2. Place the unit on a flat surface where it will not be subject to spills or impacts.
3. Route cables to the unit so that they will not be hit or pulled, causing damage to the connectors 
or to the unit itself. Ensure a sufficient flow of cool air so that the unit's operating ambient 
temperature range is not exceeded.
Circuit Protection and Earthing
When connecting the 
Unity 550
 unit to the power supply, review the ratings of all equipment in the 
circuit to ensure that the branch circuit, as well as the power source, will not be overloaded. Also make 
sure that the unit is properly grounded and/or that a protected power strip is used to attach it to the 
power supply.
WARNING:
 FCC-Mandated Suppression of Radio Frequency Emissions
This is a 
Class A
 product. In a domestic environment this product may cause radio 
interference for which the user may need to take mitigating action.
 If the Ethernet port has a cable connected to it, that cable must be properly shielded 
and grounded to minimize RF emissions that could interfere with nearby equipment.