Siemens AC75 Manuel D’Utilisation

Page de 569
AC75 AT Command Set  
4.2 AT&C
s
AC75_ATC_V01.002
Page 106 of 569
10/30/06
Confidential / Released
 
4.2
AT&C Set Data Carrier Detect (DCD) Line mode
Th
 command determines how the state of the DCD line (circuit 109) reflects the AC75's internal activity. 
Syntax
Parameter Description
[0]
DCD line shall always be on. 
1
(&F)
DCD line shall be on only when data carrier signal is present. 
2
DCD line shall be on when one or more Internet services defined on the related
serial channel are in state "Connecting" or "Up" as described below. For details
on the various service states refer to 
, parameter 
, parameter 
.
• SOCKET, HTTP, SMTP, POP3: DCD shall be on when
="Connnecting" or "Up"
• FTP: DCD shall be on when data channel is connected, i.e.
="Up"
Exec Command
AT&C
Response(s)
OK
Reference(s)
PIN
ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge
4
Last
V.250 , SIEMENS 
-
+
-
+
+
+
+
-
+
-
<value>
(num)(&W)(&V)