Siemens AC75 Manuel D’Utilisation

Page de 569
AC75 AT Command Set  
8.11 AT^SMONG
s
AC75_ATC_V01.002
Page 216 of 569
10/30/06
Confidential / Released
 
Notes
• For compatibility with earlier products and to support legacy applications, often any input character will stop
the periodic output of the write command. But since this applies only in certain cases (depending on the set-
tings of 
), it is recommended to always use "at" or "AT". 
• If the ME is Java controlled, periodic retrieval of cell information using the write command
 is not supported. If periodic cell information is required simply repeat the
execute commands at regular intervals. 
8.11.1
AT^SMONG Cell Info Table
Example output for 
Columns of the cell info table:
GPRS Monitor
BCCH  G  PBCCH  PAT MCC  MNC  NOM  TA      RAC          # Cell  #
0637  1  -      4   234  05   2    00      0B
Column
Description
BCCH
ARFCN of BCCH carrier
G
GPRS / EGPRS status:
0     GPRS / EGPRS not available in currently used cell
1     GPRS available in currently used cell
2     GPRS attached
3     EGPRS available in currently used cell
4     EGPRS attached
Note: If the network uses the PBCCH, the correct value can only be displayed if the 
AC75 is attached. 
PBCCH
If PBCCH is present, indication of ARFCN, else ''-'' or if Frequency Hopping is used ''H''
PAT
Priority Access Threshold (GSM Rec. 04.08 / 10.5.2.37b)
0     Packet access is not allowed in the cell
1     Spare, shall be interpreted as "000" (packet access not allowed)
2     Spare, shall be interpreted as "000" (packet access not allowed)
3     Packet access is allowed for priority level 1
4     Packet access is allowed for priority level 1 to 2
MCC
Mobile Country Code
MNC
Mobile Network Code
NOM
Network Operation Mode (1...3)
TA
Timing Advance Value
RAC
Routing Area Code (as hexadecimal value)