Siemens AC75 Manuel D’Utilisation

Page de 569
AC75 AT Command Set  
10.7 AT^SISR
s
AC75_ATC_V01.002
Page 280 of 569
10/30/06
Confidential / Released
 
10.7
AT^SISR Internet Service Read Data
Th
 command either triggers a read operation (download) or queries the number of bytes in the internal
buffer. 
Th
 write command may return the following errors: 
 if there is a problem on application, socket, PPP or GPRS/GSM level. The
 command and the "
" URC offer additional error information. 
 e.g. if the service has not network resources allocated. 
 e.g. if the service is not configured. 
Syntax
Unsolicited Result Code
^SISR: 
Data availability status of the Internet service configured with 
 has changed. The URC is issued when: 
• data is available after opening an Internet service or 
• less data was confirmed (i
) than requested (with 
) during the last
"Read Data" operation and new data is available. 
The URC is disabled in polling mode. See 
Parameter Description
0
Peek Operator: Query number of received bytes within internal buffers. 
The behaviour of the peek operator depends on the selected Internet service,
i.e. it may not be supported by all IP Services. 
For "Socket" service configured for UDP the size of the next available UDP
packet is returned. 
1...1500
Requested number of data bytes to be read via the Internet service specified
in 
Test Command
AT^SISR=?
Response(s)
OK 
Write Command
Response(s)
[, 
Number of data bytes are sent as specified by 
. If peek operator was used no data bytes 
are sent. 
OK 
ERROR 
PIN
ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge
4
Last
±
+
+
+
+
+
+
-
-
+
<srvProfileId>
(num)
<reqReadLength>
(num)