Siemens AC75 Manuel D’Utilisation

Page de 569
AC75 AT Command Set  
2.12 AT+CMEE
s
AC75_ATC_V01.002
Page 48 of 569
10/30/06
Confidential / Released
 
2.12
AT+CMEE Mobile Equipment Error Message Format
 controls the format of the error result codes that indicates errors related to AC75 functionality. Format
can be selected between plain "ERROR" output, error numbers or verbose "+CME ERROR: 
<err>
" and "+CMS
ERROR: 
<err>
" messages. 
Possible error result codes are listed in Table 
Table 
Tabl
 and Table
In multiplex mode (refer 
) the setting applies only to the logical channel where selected. The setting on
the other channels may differ. 
Syntax
Parameter Description
0
(&F)(D)
Disable result code, i.e. only "ERROR" will be displayed. 
1
Enable error result code with numeric values. 
2
Enable error result code with verbose (string) values. 
Example
To obtain enhanced error messages it is recommended to choose 
Test Command
AT+CMEE=?
Response(s)
+CMEE: 
(list of supported
s)
OK
Read Command
AT+CMEE?
Response(s)
OK
Write Command
Response(s)
OK 
ERROR 
+CME ERROR: 
<err>
 
Reference(s)
PIN
ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge
4
Last
GSM 07.07
-
+
+
+
+
+
+
-
+
-
<errMode>
(num)(&W)(&V)
AT+CMEE=2
OK