Functions 
 
4.10 Specify simulation settings 
 
CamTool 
4-36
 
Configuration Manual, 12.2004, 6AU1900-1AB32-0BA0 
4.10.2 
Simulation settings 
Master tab 
You specify here the simulation settings for the Master tab. 
You can set the following parameters: 
Table 4-7 
Parameters in the Master tab (Simulation Settings window) 
Field/button 
Explanation/instructions 
Setting 
 
 
Accept from axis 
• 
(Axis) 
When you create the cam for an axis that already exists 
in the project, you can select the axis here. The 
configured values are taken over and displayed. You 
can change the master velocity for calculations. 
• 
(External encoder)  
When you create the cam for an external encoder that 
already exists in the project, you can select the external 
encoder here. The configured values are taken over and 
displayed. 
• 
None  
If you select None, you can specify all parameters. 
• 
Time axis  
If you select Time axis, you can specify the unit of 
measure under Properties. 
Properties 
(Setting: None) 
(Setting: Time axis) 
 
 
Linear axis  
(Setting: None) 
If you select this option, you simulate the master axis as a 
linear axis. 
 
Rotary axis  
(Setting: None) 
If you select this option, you simulate the master axis as a 
rotary axis. 
 
Modulo rotary axis  
(Setting: None) 
If you select this option, you simulate the master axis as a 
modulo rotary axis. 
 
Type  
(Setting: None) 
Here you select the axis type. 
 
Unit of measure  
(Setting: None) 
(Setting: Time axis) 
Here you specify the unit of measure for the axis. Select a 
unit of measure or enter the unit of measure. The 
representation of the unit of measure is refreshed in the 
diagrams when you click Accept or OK.  
Note: 
The unit of measure is only used for the display. If the unit 
of measure is changed, the represented values are not 
converted.