Pass Labs X260.5 Manuel D’Utilisation

Page de 11
4
X260.5 Owners Manual
You  can  position  this  amplifier  most  anywhere  you  wish,  but  it  re-
quires  adequate  ventilation.    We  do  not  recommend  placing  it  in 
enclosed cabinets or small closets without means for air to circulate 
freely. Stacking these power amplifiers directly upon each other is not 
recommended for the same reason.  This amplifier typically idles at 
slightly more than 250 watts, most of  which dissipates as heat across 
the heatsinks. As a point of  reference, these heatsinks should never 
become too hot to touch for several seconds.
Let’s talk about AC power requirements.  This amplifier draws about 
2 amps (continuous rms) at 120 volts out of  the wall during normal 
operation, and this power draw reflects mostly the idle current that 
we run through the output stage.  If  you are driving a low impedance 
load, you will draw more power than this, but this will not be typical.
The  amplifier’s  voltage  and  current  rating  are  indicated  on  the  rear 
panel.  It will be 240 volts, 220 volts, 120 volts or 100 volts, all with 
an appropriate rear mounted replaceable type 3AG slow blow fuse.  
For units rated at either 220 or 240 volts the fuse will be a 2-1/2 amp 
type 3AG, 250V slow blow and for units rated at either 100 or 120 
volts the fuse will be a 5 amp type 3AG, slow blow.  Do not substitute 
other types, voltage, amperage or time constant fuses for the specified 
replacement.   
The frequency rating of  the AC line source in all instances will be 50 to 
60 Hz.  Please verify that the amplifiers indicated voltage requirements 
are consistent with the line voltage supplied at your location.
The Pass Laboratories™ X150.5 is provided with a conventional IEC 
detachable AC line cord, which is rated at 15 amps. The safety ground 
is attached to the chassis in the conventional approved manner.  The 
AC power input to the amplifier runs through a RF filter, which re-
moves high frequency noise coming into and going out of  the ampli-
fier power supply.
Under no circumstances should you defeat the ground connection of  
the power cord.  For your safety, the chassis of  the amplifier should be 
earth grounded.  Signal ground is isolated from chassis, safety ground, 
to  reduce  the  incidence  of   ground  loop  noise.    The  presence  of   a 
safety ground will not degrade the audio signal chain.  
You  may  substitute an  aftermarket  detachable  IEC  320  style power 
cord of  your choosing; provided it is rated for at least 15 amps and it 
meets all legal requirements and has been approved by the local testing 
authority for such things.
Setup