Manitowoc Ice C-0200 Fascicule

Page de 1
 
C, E, & H-0200 COMPRESSOR REPLACEMENT ASSEMBLIES 
                                                                                                                                        Installation Instructions 
 
Item 
Qty. 
 
Description 
 
   
 
    P/N 
   1 
Compressor Adapter Plate 
 
 
6635214 
   2 
Component Mounting Bracket 
 
 
6264614 
      3 
#10-24 x 1/2 Thread Cutting Screw  
 
5202093 
      4 
#8 Flat Head Sheet Metal Screw 
 
 
5025553 
   5 
Lead Wires        
 
 
2075623, 2075633, 2075643, 2075653, 2075663, 2075673 
   6 
Installation Instructions 
 
 
8002233 
   7 
Wire Shield 
 
 
6278414 
   8 
#10-24 Hex Nuts 
 
 
5429291 
   9 
#10 Lockwashers 
 
 
5573163 
  10 
Extruded  Tape 7 1/4” Long 
 
 
9202483 
 
ON C, E, & H-0200 SERIES ICE MACHINES 
To replace a Tecumseh compressor with a B/M number of AK159AT-032-H4, AK159ET-032-H4, or AK163JT-032-C4, items 1 
through 5 are not required.    All components are directly replaceable. 
 
To replace a Tecumseh compressor with a B/M number of AE256AT-681-A4, AE334JT-616-A4, or AE255ET-616-A4, all the items 
are required.    Follow the instructions below: 
1.  After the old compressor has been removed, fasten down the compressor adapter plate to the ice machine base.  Locate by 
using the four weldstuds, lockwashers, and hexnuts from the old compressor mounting. 
2.  Mount the new start capacitor and start relay to the component mounting bracket, as shown.  Mount this component and 
bracket assembly on the adapter plate.    Locate over the two outside weldstuds, with the components facing out, as shown. 
3.  Install the new compressor with existing sleeves, grommets, lockwashers, and hexnuts.  Note:  The compressor should be 
located so that the electrical hookup box is facing the inside of the ice machine. 
4.  New compressor refrigeration ports are not located in the same position as the original compressor refrigeration ports.  
Repiping will be required. 
5.  Using supplied wires, wire the: 
compressor protector “3” to toggle switch “17” 
start relay “L” to transformer board “19” 
start relay “M” to compressor “R” 
start capacitor to compressor “S” 
start relay “S” to start capacitor 
6.  Important:    Change the numerical marking for the compressor protector on the existing wiring diagram (on front panel label) 
to correspond with the new compressor (change the 3 to a 1 and the 1 to a 3). 
7.  On 50 Hz., 230V machines, remove the crankcase pressure regulator valve (CPR valve). 
8.  Apply wire shield (see illustration on bottom of page) to existing protruding screws of the ice machine base.    Apply tape, as 
shown on illustration. 
 
 
 
 
 
 
 
 
 
 
 
 
Manitowoc Ice, Inc.                                                                                                                                                                     
2110 South 26 Street, P.O. Box 1720, Manitowoc, WI  54221-1720 USA                                                                              
Telephone 920-682-0161, Fax - Sales:    920-683-7589, Service/Parts: 920-683-7585,    Other:  920-683-7879                              8002233 
Web Site - 
www.manitowocice.com
                                                                                                                                                                                                      Rev. 03/30/99