Technical Data
113
8.1.2
Accuracy
)
Accuracy is dependent upon various factors including the number of satellites 
tracked, constellation geometry, observation time, ephemeris accuracy, ionospheric 
disturbance, multipath and resolved ambiguities.
The following accuracies, given as root mean square, are based on measurements 
processed using LGO and on real-time measurements.
Differential code
For all receivers, the baseline precision of a differential code solution for static and 
kinematic surveys is 25 cm.
Differential phase 
in post-processing
Static
Kinematic
Horizontal
Vertical
Horizontal
Vertical
5 mm + 0.5 ppm
10 mm + 0.5 ppm
10 mm + 1 ppm
20 mm + 1 ppm