Lennox LMDV-3530CNM Manuel D'Instructions

Page de 36
36
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Printed in U.S.A. © 2005 by LENNOX HEARTH PRODUCTS
P/N  850,029M  REV. G  05/2008
 
Lennox reserves the right to make changes at any time, without notice, in design,
materials, specifications, prices and also to discontinue colors, styles and products.
Consult your local distributor for fireplace code information.
1110 West Taft Avenue • Orange, CA  92865
Figure 68
Retaining
Clip
Ignitor
Assembly
Pilot
Assembly
Pilot
Orifice
Flare Nut
Figure 69
Step 8. Reassemble all removed components
by  reversing  the  procedures  outlined  in  the
preceding steps. Use pipe joint compound or
Teflon tape on all pipe fittings before installing
(ensure propane resistant compounds are used
in propane applications, do not use pipe joint
compounds on flare fittings).
Step 9. Attach the conversion label provided
in the conversion kit to the rating plate on the
appliance.
Step 10. Turn on gas supply and test for gas
leaks.
All Models
Step  7.  Remove  the  burner  orifice  from  the
manifold and replace it with the one provided
with  the  kit.  See
Table  14  for  orifice  sizes
required for use with natural gas or propane
gas. Figure 69  illustrates the orifice.
Step 6. Electronic Appliances -
 
Honeywell Systems
See Figure 67  and the instructions provided 
with the kit.  Remove the slotted cap screw, 
o-ring, pressure-regulating adjusting screw 
and  spring.    Retain  all  parts  for  possible 
later use.  Install new components from the 
kit.  Black cap and red spring for propane gas 
units.  Silver cap and stainless steel spring 
for natural gas units.  
Before installing the cap, attach manometer 
to the manifold side pressure test fitting and 
adjust screw until pressure reads 3.5 inches 
water  column  (0.87  kPa)  for  natural  gas, 
and 10.0 inches water column (2.49 kPa) for 
propane gas.
See Figure 68 and replace the pilot orifice 
as  follows:    Remove  the  Igniter  assembly 
retainer clip, and carefully remove the Igniter 
assembly.
Exercise extreme care to prevent damage to or 
breakage of the Igniter assembly.  Remove the 
screw securing the pilot assembly to its mount-
ing bracket.  Back off the flare nut at the end 
of the pilot gas line to free the pilot assembly 
from the gas line.  Remove the pilot orifice 
and replace it with the one provided with the 
conversion kit.  Reinstall the pilot assembly 
by reversing the steps detailed here. 
When reinstalling the Igniter assembly, use 
extreme care to prevent damage and break-
age.  Do not apply any leverage to the Igniter 
assembly while restoring the retainer clip to 
its original position.
Figure 67
Spring
Adjusting
Screw
Slotted
Cap
P
S
I
OFF
I
ON
CONTROL
IG
N
IT
E
Manifold
Pressure
Test Port
Inlet Pressure Test Port
Burner Orifice Sizes 
Elevation 0-4500 feet ( 0-1372 meters)
Model
Series
Natural
Gas
drill 
sizez(inches)
Propane
Gas
drill size (inches)
LMDVT-3328
LMDVR-3328
#45 (.082") 
*
39L66 •
1.2mm (.048") 
*
99K78
LMDV-3530
#44 (.086") 
*
60J8001 •
#55 (.052") 
*
19L5201
LMDV-4035
#37 (.104") 
*
24M1001 •
1/16" (.062")
*
21L0101 •
* Standard size installed at factory
•  Part /Cat. Number
Table 14
Note:  If  the  Igniter  is  damaged,  a  replacement  kit  is  available  -  order  Catalog  Number 
87L54.