Gilson Minipuls 3 Fascicule

Page de 2
High Performance
Peristaltic Pump
World Wide Web: www.gilson.com
E-mail: sales@gilson.com, service@gilson.com, training@gilson.com
World Headquarters
Gilson, Inc.
3000 W. Beltline Hwy., P.O. Box 620027, Middleton, WI 53562-0027, USA
Telephone: (1) 800-445-7661 or (1) 608-836-1551 • Fax: (1) 608-831-4451
Gilson S.A.S.
19, avenue des Entrepreneurs - BP 145, 95400 Villiers le Bel, France
Telephone: (33) 1-34-29-50-00 • Fax: (33) 1-34-29-50-20
LT800443E. Printed in France, May 2003. Specifications subject to change without notice.
Gilson, Inc., Gilson S.A.S., and Cyberlab, Inc. are ISO certified. 
ISO 9001 
Certified
Ordering Information
Gilson’s Minipuls 3 is available as two parts: a speed control module and a pump head. 
An accessory package is suplied with the speed control module.
Item
Reference N°
Speed-Control Module
F155001
R1 Pump Head
F117604
R2 Pump Head
F117800
R4 Pump Head
F117606
R8 Pump Head
F117608
R2/HF (high-flow) Pump Head 
F117830
R4/HF (high-flow) Pump Head
F117831
Technical Specifications
Flow Rate
Standard Model: 0.3 µL/min to 30 mL/min (72 psi/5 bar/0.5 MPa max)
High Flow Model: 1 mL/min to 220 mL/min (42 psi/3 bar/0.3 MPa max)
Pump Head
Standard Model: 1,2,4 or 8 channel heads with 10 stainless steel rollers per head
High Flow Model: 2 or 4 channel heads with 5 stainless steel rollers per head
Head Speed
Continuous adjustment from 0 to 48 rpm by 0.01 rpm increments 
up to 9.99 rpm and by 0.1 increments  above 10 rpm
Peristaltic Tubing Diameter
Standard Model: 0.25 to 4 mm (i.d.)
High Flow Model: 2 to 8 mm (i.d.)
Tubing materials
PVC for most applications, Viton for chemical inertness, silicone for biocompatibility,
and Pharmed(r) for FDA and USP class 4.
Motor Speed Stability
0.5% for any variation of line voltage, torque or temperature
Line Voltage
90V to 132V for 110 voltage selection: 180V to 264V for 220 voltage selection
Line Frequency
47 to 63 Hz
Power Consumption
Full load 45 W at 220V; no load 35 W at 220V
Operating Temperature
0-40° C No warm-up time required
Input/Output Options
Contact Closure: Two TTL-compatible inputs for control of start/stop and direction of flow
Voltage Input: One 5 V analog signal for variable control of motor speed
Serial: Gilson Serial Input/Output Channel (GSIOC), an RS-422A interface
Keypad functions
Start, stop, direction of flow, increase and decrease flow, prime.
Dimensions (w x h x d)
15 x 18 x 17.5 cm (5.0 x 7.1 x 6.9 in)
Weight
4 kg (9 lbs)
... wide range of flow-rates,