Always  consult  your  local  Building  Department  regarding 
regulations, codes or ordinances which apply to the installation 
of a vented fireplace heater.
Instructions to Installer
1.  Installer  must  leave  instruction  manual  with  owner  after 
installation.
2.  Installer  must  have  owner  fill  out  and  mail  warranty  card 
supplied with heater.
3.  Installer should show owner how to start and operate heater 
and thermostat.
General Information 
This appliance is design certified in accordance with American 
National Standard /CSA Standard ANSI  Z21.88 and CSA 2.33 by 
the Canadian Standards Association, as a Vented Fireplace Heater 
and must be installed according to these instructions. 
Any  alteration  of  the  original  design,  installed  other  than 
as shown in these instructions or use with a type of gas not 
shown on the rating plate is the responsibility of the person 
and company making the change.
Important
All  correspondence  should  refer  to  complete  Model  Number, 
Serial Number and type of gas.
Notice: During initial firing of this unit, its paint will bake out 
and smoke will occur. To prevent triggering of smoke alarms, 
ventilate the room in which the unit is installed.
Qualified Installing Agency
Installation  and  replacement  of  gas  piping,  gas  utilization 
equipment or accessories and repair and servicing of equipment 
shall be performed only by a qualified agency. The term "qualified 
agency"  means  any  individual,  firm,  corporation  or  company 
which either in person or through a representative is engaged in 
and is responsible for (a) the installation or replacement of gas 
piping or (b) the connection, installation, repair or servicing of 
equipment, who is experienced in such work, familiar with all 
precautions required and has complied with all the requirements 
of the authority having jurisdiction.
State  of  Massachusetts:  The  installation  must  be  made  by 
a  licensed  plumber  or  gas  fitter  in  the  Commonwealth  of 
Massachusetts.
The installation must conform with local codes or, in the absence 
of local codes, with the National Fuel Gas Code, ANSI Z223.1/
NFPA 54.*
*Available from the American National Standards Institute, Inc., 11 West 42nd 
St., New York, N.Y. 10036.
 
High Altitudes
When installing this unit at an elevation above 2000 feet (in the 
United States) it may be necessary to decrease the input rating by 
changing the existing burner orifice to a smaller size. Generally, 
input should be reduced 4 percent for each 1000 feet above sea 
level. However, if the heating value of the gas has been reduced, 
this general rule may not apply. Check with local gas utility for 
proper orifice size identification.
APPLIES TO CANADIAN MODELS ONLY FOR PROPANE 
GAS.
Altitude: 0-4,500 feet (0-1370 m) without orifice change.
APPLIES TO CANADIAN MODELS ONLY FOR NATURAL 
GAS.
Altitude 0-2,000 feet (0-610m) without orifice change.
Cet appareil est équipé pour des altitudes compris entre 0 et 
2000 pieds (0-610m) seulement.
For installations from 610-1370 metres (2,000-4,500 ft.) the 
orifice size (DMS) for natural gas is 39. See data plate for 
additional information. 
For high altitude installations consult the local gas distributor or 
the authority having jurisdiction for proper rating methods. If the 
installer must convert the unit to adjust for varying altitudes, the 
information sticker (illustrated below) must be filled out by the 
installer and adhered to the appliance at the time of conversion.
THE CONVERSION SHALL BE CARRIED OUT BY A MAN-
UFACTURER'S AUTHORIZED REPRESENTATIVE IN AC-
CORDANCE WITH THE REQUIREMENTS OF THE MANU-
FACTURER, PROVINCIAL OR TERRITORIAL AUTHORITIES 
HAVING JURISDICTION AND IN ACCORDANCE WITH THE 
REQUIREMENTS OF THE CAN/CGA-B141.1 OR CAN/CGA-
B141.2 INSTALLATION CODES.
LA  CONVERSION  DOIT  ÊTRE  EFFECTUÉE  CONFOR-
MÉMENT  AUX  RÉGLEMENTATION  PROVINCIAUX  EN 
CAUSE ET AUX EXIGENCES DES CODES D'INSTALLATION 
CAN/CGA-B149.
This appliance has been converted for use at an altitude of 
Orifice size 
 
Manifold Pressure 
Input (Btu/h) 
 
Fuel Type 
Date of Conversion 
 
Converted by 
Cet appareil a été converti au 
Injecteur 
  Pression à la tubulure d'alimentation 
Déoit calorifique 