Ferguson JWSH100150 Manuel D’Utilisation

Page de 36
18
ACTION: 
To get to the current fault information screen, press 
Menu.
DISPLAY:
ACTION: 
Press the
 DOWN button to highlight "current Fault" and press Select.
DISPLAY:
ACTION: 
Press the 
DOWN button for more information.
DISPLAY:
7.  Viewing the Fault History
The controller for this water heater will store a history of ten of the last Fault 
and Warning conditions that occurred.  This is stored in the Fault History.   
Along with all the information about the fault, including a estimate time of 
when the fault occurred, information regarding the advanced diagnostics for 
that fault can be accessed at any time. 
 
ACTION: 
Press the 
DOWN button for more information.
DISPLAY:
ACTION: 
Press the 
DOWN key to scroll through the fault history.   If you select a 
specific fault or warning, you may press the 
VIEW button to view details 
regarding this fault.
DISPLAY:
8.  Viewing Information About the Heater
The electronic control for this water heater monitors many different aspects 
of the water to ensure safe and optimal operation.   Much of the information 
monitored is available to view in two areas of the control.   The first is the 
"Heater Status" and; the second is "Heater Information." These items can be 
selected through the main menu in the same fashion as described above.   
In these menus, detailed information about the water heater and the current 
status of specific conditions can be found. 
INSTALLATION  OR  SERVICE  OF  THIS  WATER  HEATER  REQUIRES 
ABILITY EQUIVALENT TO THAT OF A LICENSED TRADESMAN IN THE 
FIELD  INVOLVED.  PLUMBING, AIR  SUPPLY,  VENTING,  GAS  SUPPLY 
AND ELECTRICAL WORK ARE REQUIRED.
Before attempting start-up, thoroughly study and familiarize yourself with 
the exact sequence of operation and all other details on the specific heater 
being used.
The power burner is equipped with an ignition system which automatically 
sequences prepurge and ignition, senses and ignites main burner flame and 
sequences burner operation. Heater is equipped with an ignition control which 
locks out after three unsuccessful ignition attempts. Familiarize yourself with 
the sequence of operation of this unit prior to start-up.
Be certain that the water heater is full of water, that air is purged from all lines, 
there are no leaks (gas and water), and all inlet water lines are open.
The following test equipment should be on hand (all test equipment must be 
acclimated to ambient temperature before calibration and use.)
–  Two  U-tube  manometers  or  calibrated  pressure  gages  that  can  read 
 0-10" (0-2.5Kpa) and 0-35" (0-8.7Kpa) W.C. pressure gauges.
•  Attach  a  gas  pressure  gauge  or  manometer  to  the  upstream  side  of 
main gas cock and a gas pressure gauge or manometer to the manifold 
pressure tap.
•  You are now ready to begin the burner start-up procedure.
PRIOR TO START UP
REQUIRED ABILITY