Soundolier AA35 Manuel D’Utilisation

Page de 24
 
Specifications are subject to change without notice
 AtlasSound.com
1601 JACK MCKAY BOULEVARD ENNIS, TEXAS 75119 U.S.A.   •    TELEPHONE: (800) 876-3333   •   FAX: (800) 765-3435
©2006 ATLAS SOUND LP 
Printed in U.S.A. 
000106 
ATS002171 RevA 01/06 
PP 
OWNER'S MANUAL
AA35 MIXER AMPLIFIER
7
9.   Treble Control
 
Normally set at the 12:00 position, rotating clockwise will increase (boost) treble frequencies by 10dB 
 
at 10kHz. Rotating counter-clockwise from the 12:00 position will decrease (cut) treble frequencies by   
 
10dB at 10kHz.
 
REAR PANEL DESCRIPTION
10. Multi Function Dipswitch
 
Understanding the functionality of the dipswitches is key to maximizing the versatility of the AA35.  
 
When a switch is in the up position, the function is "OFF"; when a switch is in the down position, the  
 function 
is 
"ON".
 
SWITCH 1- Zone 2 Assign - When "ON", will route signals from Input 3 to the Zone 2 Output  
 
 terminals.
 
SWITCH 2- Zone 2 Assign - When "ON", will route signals from Input 2 to the Zone 2 Output  
 
 terminals.
 
SWITCH 3- Zone 2 Assign - When "ON", will route signals from Input 1 to the Zone 2 Output  
 
 terminals.
   
SWITCH 4 - Mute Receive - When "ON", Input 3 signals will be muted if a signal is present on
   
Input 1 (Refer to Mute Sensitivity Control, number 16 on page 9), or if a contact closure is  
 
   
present on the remote mute terminals (Refer to Remote Mute Connector, number 11(B) on page   
  
8).
 SWITCH 
- Mute Receive - When "ON", Input 2 signals will be muted upon a signal present on   
 
Input 1(Refer to Mute Sensitivity Control, number 16 on page 9), or if a contact closure is present  
 
on the remote mute terminals (Refer to Remote Mute Connector, number 11(B) on page 8).
On
Off
Low cut
8
On
Off
4
3
2
1
Phantom
Mute Rcv
Off
On
Off
On
Off
On
Off
On
5
Zone 2 Assign
6
Input 3
Input 2
Input 1
Input1
7
Input 2
Input 3
Line/Tel
Mic
Off
On
Unswitched Outlet  
120V  AC  60Hz 
Max 500W
Outlet Breaker 
125V AC 4A 
Push Reset
120V AC 60Hz 100W  
           
Amp In
Line Out A
Line Out B
Pre Out
Input 3
Input 2
L
R
Zone2
10
0
Level
Mute
Sens
10
0
Remote
Mute
G
-
+
Input 1
¡
8
1W
¡
600
Zone 2 Out
-
+
-
+
Speaker Output 35W
COM
25V
¡
8
70V
L
R
£Èä£Ê>VŽÊV>ÞÊ Û`°]Ê ˜˜ˆÃ]Ê/8ÊÇx££™Ê
­nää®ÊnÇȇÎÎÎÎÊ̏>Ã-œÕ˜`°Vœ“
77)+
7jbWiIekdZ77I[h_[iC_n[h7cfb_\_[h
CLASS 2 WIRING
10
On
Off
Low cut
8
On
Off
4
3
2
1
Phantom
Mute Rcv
Off
On
Off
On
Off
On
Off
On
5
Zone 2 Assign
6
Input 3
Input 2
Input 1
Input1
7
Input 2
Input 3
Line/Tel
Mic
Off
On