Sunpentown Intl Sunpentown Intl. Inc. Telephone FM-8800D/8800S Manuel D’Utilisation

Page de 129
1. OPERATIONAL OVERVIEW 
 
 
 
1-7
 
Alarm Frequency 
(interval) 
Safety call received 
1300 Hz and 0 Hz (250 ms) 
Routine, Ship’s Business call received 
880 Hz and 440 Hz (500 ms) 
While DISTRESS key is pressed for 
three seconds 
2200 Hz and 0 Hz (125 ms) 
Distress alert sent 
2200 Hz, continuous 
Own ship position not updated 
2200 Hz (50 ms), three beeps every two 
seconds 
Distress alert, urgency message 
received 
1300 Hz and 2200 Hz (250 ms) 
Message received from terrestrial 
telephone line 
750 Hz and 650 Hz (50 ms) 10 times 
Repeat OFF one second 
 
1.2 
VHF Basic Operation 
1.2.1 
Turning the power on and adjusting contrast
 
To turn the power on, turn the VOLUME control clockwise until you hear a click. 
To adjust the contrast of the display, press the SHIFT key, and then rotate the 
CHANNEL knob or press the ▼ or ▲ key. To turn the power off, turn the control 
fully counterclockwise until you hear the click.
 
 
1.2.2    Selecting channel modes, channels 
Selecting channel modes 
To change the channel mode, press the SHIFT key immediately followed by the 
7 INT/USA key several times until desired mode is displayed. The following 
modes are available. 
INTL  
: International mode 
USA   
: USA mode 
WX    
: Weather channel mode 
CANADA 
: CANADA mode 
INLND-WA  : Rhine river mode (USED ON INLAND Waterways) 
PRIV  
: Private channel 
MEMO 
: Memory channel mode if registered 
 
Note:  Private channels are available only where permitted by the authorities. 
The USA/WX, CANADA, INLND-WA , PRIV can also be set by a qualified 
serviceman. 
 
Selecting channels 
Rotate the CH selector clockwise (counterclockwise) to display desired channel. 
Use [2] key or [8] key at the remote station to set private channel or memory 
channel.