Sunpentown Intl Sunpentown Intl. Inc. Telephone FM-8800D/8800S Manuel D’Utilisation

Page de 129
6. MAINTENANCE & TROUBLESHOOTING 
 
 
 
6-2 
6.3 Daily 
Test 
Authorities require that the DSC be checked daily for proper operation to ensure 
that it will function properly in the event of distress. Execute the daily test as 
below.  
   
1. At the standby display, press the SHIFT key and TEST key in that order. The 
following display appears for test. And distress alarm (visual and audible) 
occurs. 
*** DAILY TEST ***
TX POWER     : OK
TX/RX PCB     : OK
CPU PCB        : OK
CH70 RX PCB : OK
DUP RX PCB   : OK
Test in progress
(Pop-up display appears momentarily.)
If you have not pressed the PTT switch
before executing the test, "NO CHECK"
is displayed.
FM-8800D only
 
Result of daily test 
 
2. To stop ALARM, press the CANCEL key. 
3. To stop the daily test, press the CANCEL key. 
   
 “NG” may be displayed depending on the receiving conditions. In this case, repeat 
the daily test a couple of times. If NG is displayed always, contact a FURUNO agent 
or representative for advice. 
 
The table below shows the abnormal indications and causes shown in the daily test.   
Indication Cause 
TX POWER: NG 
Indicates no transmitting output power. 
PA module or TX/RX pcb 05P0774 may be damaged. 
TX/RX PCB: NG 
Indicates abnormal PLL circuit in the TX/RX pcb. 
TX/RX pcb 05P0774 may be damaged. 
CPU PCB: NG 
Indicates abnormal loop circuit inside the CPU board. 
CPU pcb 05P0773 may be damaged. 
CH70 RX PCB: NG 
Indicates abnormal loop circuit between CPU and CH70 
RX pcb. CH70 RX pcb 05P0775
 
may be damaged. 
DUP RX PCB: NG 
Indicates abnormal PLL circuit in the DUP RX pcb. 
DUP RX pcb 05P0777 may be damaged. 
If necessary, refer to Parts Location on subsequent pages. 
 