Sterling Wheelchair AF-XXX Manuel D’Utilisation

Page de 55
Additive Feeders 
Chapter 6: Maintenance 
40 of 55 
6-2 Preventative 
Maintenance 
This section describes maintenance procedures which will increase the longevity and 
efficiency of your additive feeder.  Perform them at the regular intervals listed on the 
checklist on the previous page. 
Material Cleanout/Changeover 
Caution! 
Never put hands or tools in or near the auger assembly when power is 
connected!  
Do not wear gloves or loose clothing when working near the auger 
assembly! 
 
 
1.   Remove all remaining additive from the supply hopper by opening the cleanout 
hatch.  The motor assembly must be disengaged to fully open the cleanout hatch. 
2.   Re-engage the motor assembly and run any remaining additive out of the feeder by 
opening the calibration hatch and holding the three-position motor switch in the 
MANUAL position. 
3.   Disengage the motor assembly and remove the auger.  Release the insert by pulling 
the auger insert release knob on the side of the material transfer tube assembly.  
Slide the insert out through the motor end of the transport tube.  Clean both the 
auger and the insert. 
4.   Clean the interior of the supply hopper and any additive remaining in the 
calibration or cleanout hatches.