Siemens TV Converter Box 611 Manuel D’Utilisation
Technical data and characteristics
14.2 Data sheets and diagrams
Data sheet 1FW6130-xxB07-xxxx
Table 14- 6 1FW6130-xxB07-0Kxx, 1FW6130-xxB07-1Jxx
Technical data
1FW6130
1FW6130
Symbol
Unit
-xxB07-0Kxx -xxB07-1Jxx
Boundary conditions
DC link voltages
U
ZK
V
600
600
Water cooling inlet temperature
T
VORL
°C
35
35
Rated temperature of winding
T
N
°C
130
130
Rated data
Rated torque
M
N
Nm
344
324
Rated current
I
N
A
10
15
Maximum speed at rated torque
n
MAX,MN
rpm
96
200
Rated power dissipation
P
V,N
kW
3.73
3.71
Limit data
Maximum torque
M
MAX
Nm
614
614
Maximum current
I
MAX
A
20
32
Electric power of motor at M
MAX
P
EL,MAX
kW
14.2
19.7
Maximum speed at maximum torque
n
MAX,MMAX
rpm
21
110
No-load speed
n
MAX,0
rpm
190
300
Torque at n = 1 [rpm]
M
0
Nm
361
361
Current at M
0
and n = 1 [rpm]
I
0
A
10
17
Thermal static torque
M
0
*
Nm
256
256
Thermal stall current
I
0
*
A
7.6
12
Physical constants
Torque constant at 20 °C
k
T,20
Nm/A
34
21.4
Voltage constant
k
E
V/(1000/min)
2056
1295
Motor constant at 20 °C
k
M,20
Nm/(W)
0.5
6.11
6.13
Thermal time constant
t
TH
s
60
60
No. of pole pairs
p
-
33
33
Cogging torque
M
COG
Nm
1.8
1.8
Stator mass
m
S
kg
11.9
11.9
Rotor mass
m
L
kg
6.3
6.3
Rotor moment of inertia
J
L
10
-2
kgm
2
8.92
8.92
Phase resistance of winding at 20 °C
R
STR, 20
Ω
7.41
2.92
Phase inductance of winding
L
STR
mH
21
8.3
Data, main motor cooler
Maximum dissipated thermal power
Q
H,MAX
kW
3.1
3.09
Recommended minimum volume flow rate
H,MIN
l/min
5.2
5.2
Temperature increase of the coolant
ΔT
H
K
8.6
8.5
Pressure drop
Δp
H
bar
0.2
0.2
1FW6 Built-in torque motors
214