Rinnai ES38 (RHFE-1004FTA) Manuel De Montage

Page de 80
 
24 
Rinnai Corporation ES38 Manual 
 
  Extension Kit Installation   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
If necessary, extension kits are available to extend the 
exhaust line and air intake hose between the manifold 
and the appliance.  The maximum vent length is 13 feet 
(4 m) with 2 bends.  The bent pipe attached to the 
appliance does not count toward the max limit of 2 
bends.   
Horizontal sections should be sloped 3º to drain 
condensate.  (3º equals 2/3 inch drop per foot of vent.)  
The direction should be to the outside (if local codes 
allow) or toward the appliance.  Do not allow any low 
points in the exhaust line where condensate will collect.   
Vent extensions installed in unconditioned air space 
must be insulated with high temperature insulation and 
must be accessible. 
Vent extensions must not be concealed per NFPA 54 
and must be accessible allowing inspection and repair.  
Decorative covers are available from Rinnai. 
INCORRECT 
•  Too many bends (limit is 2) 
•  Air intake hose is above 
exhaust pipe 
CORRECT 
3
1 foot
2/3 inch
Slope horizontal sections 3º (2/3 inch drop per foot of vent.)