  Connecting the Appliance   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1.  Attach flue adapter to the flue manifold with 
pipe stopper S. 
2.  Attach the air inlet hose to the flue manifold.  
Secure with plastic tie.  The unused inlet is 
plugged with the rubber cap supplied on the 
manifold. 
3.  Connect the vent sliding tube with pipe 
stopper S and E.  The sliding tube should 
not be extended beyond the red line.  The 
red line should not be visible after sliding 
the tube into the vent outlet. 
4.  Slide the insulation sleeve up to the flue 
manifold and slip the securing clip over the 
sleeve as shown. 
5.  Attach the appliance to the wall brackets, 
using 2 screws at each bracket. 
6.  Attach the back spacer with 3 screws to the 
top of the appliance. 
Inlet hose
Inlet elbow
Plastic tie
7.  If necessary, the appliance can be leveled 
using the adjustable legs under the front 
right and left legs. 
Screw
Sliding Tube
PIPE STOPPER S
PIPE STOPPER A
Flue Manifold
PIPE STOPPER E
Pipe stopper S
Flue Manifold
Flue Adapter
SCREW
M5)