Tektronix Camcorder 2200 Manuel D’Utilisation

Page de 316
3-85
E-MEM Menu
For 
LOCK REG
:
LOCK ALL
,
 UNLOCK ALL
 — Locks or unlocks all 100 registers 
for all currently enabled “levels.” (Levels are enabled with the 
Enable buttons on the E-MEM panel - for a definition of levels, 
refer to Enable Buttons, Effects Memory Subpanel, this 
section.) If any registers are unlocked, a
 LOCK ALL 
selection is 
displayed; if any or all registers are locked, an
 UNLOCK ALL
 
selection is displayed.
LOCK BANK
,
 UNLOCK BANK
 — Locks or unlocks all registers 
in the currently displayed bank and register for all currently 
enabled levels. Note that the current bank displayed may not 
be the same as the current bank for independent E-MEM 
levels. If that is the case, the current bank will not get locked 
on those levels, but the selected bank will.
If any currently enabled E-MEM level has an unlocked 
register in the bank, a
 LOCK BANK 
instruction is displayed for 
the currently displayed bank number. When all registers in 
the bank are locked, an
 UNLOCK BANK 
instruction is 
displayed.
LOCK REG
,
 UNLOCK REG
 — Locks the register whose number 
is displayed in the menu for all currently enabled levels. Note 
that this may not be the current register for some levels. If that 
is the case, the current register will not get locked on those 
levels, but the selected register will.
If any currently enabled E-MEM register level is unlocked, a 
LOCK REG
 instruction is displayed for the currently displayed 
register number. When all of the enabled E-MEM register 
levels are locked, an
 UNLOCK REG 
instruction is displayed.