Tascam DS-M7.1 Manuel D’Utilisation

Page de 40
3 – Connections
  TASCAM DS-M7.1 
15
Console
 and 
MasterRec
 (mastering 
recorder).
The second and third lines of the screen will 
be automatically filled in depending on both 
the source and the settings made elsewhere in 
the system as described in “Routing and 
patching” on page 19. P
ossible values are:
NOTE
High-speed connections cannot be made using the TAS-
CAM DM-24 digital mixing console. They may not be 
supported by other equipment, and you should check 
carefully in the documentation of all the components of 
your system to ensure that this is a valid option.
Only the analog and AES/EBU connections and option 
cards support 96k operation on the DS-M7.1.
Inverting the word clock
In some cases, the polarity of the word clock received 
at the 
WORD IN
 connector may be inverted relative 
to what the DS-M7.1 expects (since no industry stan-
dard has been universally adopted). In this case, you 
may need to invert the polarity of the clock so that it 
syncs accurately with the other devices in the setup.
1
Press the 
SYSTEM
 key, and use the cursor 
keys until a screen similar to the following 
appears:
2
Switch the 
WordIN
 parameter between 
Normal
 and 
Reverse
.
Word clock errors
In the event of a word clock error, the display back-
light flashes, the output is muted, and the screen 
shows 
[SYSTEM] *n
 where 
n
 is a number rep-
resenting the error, as explained below:
Source
Possible sources
Possible sampling 
frequencies (kHz)
Word In
Word In only
44.1, 48, 88.2, 96
Console
TDIF (internal)
44.1, 48
EX TDIF (slot)
44.1, 48
EX AES/EBU (slot)
44.1, 48 (normal), 
88.2, 96 (high)
EX ADAT (slot)
44.1, 48
Master Rec
TDIF (internal)
44.1, 48
AES/EBU (internal)
44.1, 48 (normal), 
88.2, 96 (high)
ADAT (internal)
44.1, 48
[ S Y S T E M ]
< >
L F E G a i n
+ 1 0 d B
S o l o
E x l u s i v e
W o r d I N
N o r m a l
Error 
number
Meaning
Appropriate action to take
0
No master clock.
 Check the connections between the DS-M7.1 and the clock master, and check the set-
tings on the clock master to ensure that it is actually outputting a word sync signal.
1
Master clock out of range (44.1 kHz)
Check the settings of the clock master, and make sure that it is within ±6% of the 
stated nominal frequency
2
Master clock out of range (48 kHz)
3
Master clock out of range (88.2 kHz)
4
Master clock out of range (96 kHz)