Chimney Installation: 
 
Do not connect this unit to a chimney flue serving another appliance.  Do not connect to any 
air distribution duct or system

 
The SCAN A10 stove is listed for installation as a vertically top or rear vented stove using a listed 
class A (UL103HT) for Canada (CAN/ULC-S629) factory built chimney exiting through the 
ceiling/attic/roof. The inside diameter of the chimney, connector pipe must not be smaller than 6” 
(152 cm) diameter. Single wall 24 gauge MSG (0.58 – 0.71 mm) and adapter must not be smaller 
than 6” (152 mm), may be used in the room where the stove is installed, follow the chimney 
manufacturer’s instruction for installation of chimney and chimney adapter. In Canada, where 
passage through wall, or partition of combustible construction is desired, the installation shall 
conform to CAN/CSA B365. 
   
Factory Built Chimney 
When a metal prefabricated chimney is used, the manufacturer’s installation instructions must be 
followed. You must also purchase (from the same manufacturer) and install the ceiling support 
package or wall pass-through and “T” section package, fire stops (where needed), insulation shield, 
roof flashing, chimney cap, etc. Maintain proper clearance to the structure as recommended by the 
manufacturer. The chimney must be the required height above the roof or other obstructions for 
safety and proper draft operation.  See page 15 for Chimney Height Requirements
 
Masonry Chimney  
Ensure that a masonry chimney meets the minimum standards of the National Fire Protection 
Association (NFPA) by having it inspected by a professional.  Make sure there are no cracks, loose 
mortar or other signs of deterioration and blockage.  Have the chimney cleaned before the stove is 
installed and operated. When connecting the stove through a combustible wall to a masonry 
chimney, special methods are needed. Refer to Combustible Wall Chimney Connector Pass-
Throughs on page 14. 
 
Top vent installation
  
Mounting of the flue collar for top vent. 
Turn the flue collar around and fix the 
brackets under the top plate. 
Tighten the two screws with the delivered   
hexagon spanner (tighten well) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Required installation components: 
•  Chimney cap 
•  Insulated chimney 
•  Storm collar 
•  Roof flashing 
•  Ceiling support box or joist 
shield/fire stop spacer 
•  Chimney connector pipe 
•  Chimney connector adapter